APMonitor Options Overview
Main.DBS History
Hide minor edits - Show changes to markup


Global configuration parameters control the overall options for the application and are read before the model is parsed or data is input into the model structure. These parameters are read regardless of the value of APM.DBS_READ. When APM.DBS_READ = 0 (OFF) only the options associated with variables are skipped.
The database file contains options and model inputs. The following is an exhaustive list of the configuration parameters for APM type and FV, MV, SV, CV type. Each section (Global and Variables) includes an indication of the variable type (Integer or Real), the default value, data flow, and description.
The database file contains options and model inputs. The following is an exhaustive list of the configuration parameters for APM type and FV, MV, SV, CV type. Each option (Global or Local) includes an indication of the variable type (Integer or Real), the default value, data flow, and description.
FV, MV, SV, and CV Options
FV, MV, SV, and CV (Local) Options
Local options are associated only with parameters declared as Fixed Values (FVs) or Manipulated Variables (MVs) and variables declared as State Variables (SVs) or Controlled Variables (CVs). These options are not read when APM.DBS_READ = 0 (OFF)''.
Local options are associated only with parameters declared as Fixed Values (FVs) or Manipulated Variables (MVs) and variables declared as State Variables (SVs) or Controlled Variables (CVs). These options are not read when APM.DBS_READ = 0 (OFF).










- APM.APPINFO
- APM.APPINFOCHG
- APM.APPSTATUS
- APM.AUTO_COLD
- APM.BAD_CYCLES
- APM.BNDS_CHK
- APM.COLDSTART
- APM.CSV_READ
- APM.CSV_WRITE
- APM.CTRL_HOR
- APM.CTRL_TIME
- APM.CTRL_UNITS
- APM.CTRLMODE
- APM.CV_TYPE
- APM.CV_WGT_SLOPE
- APM.CV_WGT_START
- APM.CYCLECOUNT
- APM.DBS_LEVEL
- APM.DBS_READ
- APM.DBS_WRITE
- APM.DIAGLEVEL
- APM.EV_WGT_SLOPE
- APM.EV_TYPE
- APM.FILTER
- APM.FRZE_CHK
- APM.HIST_HOR
- APM.HIST_UNITS
- APM.ICD_CALC
- APM.IMODE
- APM.ITERATIONS
- APM.LINEAR
- APM.MAX_ITER
- APM.MAX_MEMORY
- APM.MAX_TIME
- APM.MEAS_CHK
- APM.MV_DCOST_SLOPE
- APM.MV_STEP_HOR
- APM.MV_TYPE
- APM.NODES
- APM.OBJFCNVAL
- APM.OTOL
- APM.PRED_HOR
- APM.PRED_TIME
- APM.REDUCE
- APM.REPLAY
- APM.REQCTRLMODE
- APM.RTOL
- APM.SCALING
- APM.SENSITIVITY
- APM.SEQUENTIAL
- APM.SOLVER
- APM.SOLVESTATUS
- APM.SOLVETIME
- APM.SPECS
- APM.SPC_CHART
- APM.STREAM_LEVEL
- APM.TIME_SHIFT
- APM.WEB
- APM.WEB_MENU
- APM.WEB_REFRESH
- APM.WEB_PLOT_FREQ
Example DBS File
Options are stored in DBS files. When an option is changed with a call to apm_option, a line is added to the overrides.dbs file. When a measurement is recorded with apm_meas, a line is added to measurements.dbs. Below is an example of a DBS file with both global application options and options for individually classified parameters and variables.
APM.APPINFO = 0, 1 APM.APPINFOCHG = 0, 1 APM.APPSTATUS = 1, 1 APM.BNDS_CHK = 1, 1 APM.COLDSTART = 0, 1 APM.CSV_READ = 0, 1 APM.CSV_WRITE = 0, 1 APM.CTRL_HOR = 1, 1 APM.CTRL_TIME = 0.6000000000000000D+02, 1 APM.CTRL_UNITS = 1, 1 APM.CTRLMODE = 1, 1 APM.CV_WGT_SLOPE = 0.0000000000000000D+00, 1 APM.CV_WGT_START = 0, 1 APM.CV_TYPE = 1, 1 APM.CYCLECOUNT = 70, 1 APM.DBS_READ = 0, 1 APM.DBS_WRITE = 1, 1 APM.DIAGLEVEL = 0, 1 APM.EV_WGT_SLOPE = 0.0000000000000000D+00, 1 APM.EV_TYPE = 2, 1 APM.HIST_HOR = 0, 1 APM.HIST_UNITS = 0, 1 APM.ICD_CALC = 0, 1 APM.IMODE = 3, 1 APM.ITERATIONS = 0, 1 APM.MAX_ITER = 25, 1 APM.MAX_TIME = 0.1000000000000000D+21, 1 APM.MEAS_CHK = 1, 1 APM.MV_DCOST_SLOPE = 0.1000000000000000D+00, 1 APM.MV_STEP_HOR = 1, 1 APM.MV_TYPE = 0, 1 APM.NODES = 4, 1 APM.OBJFCNVAL = 0.0000000000000000D+00, 1 APM.OTOL = 0.1000000000000000D-05, 1 APM.PRED_HOR = 3, 1 APM.PRED_TIME = 0.6000000000000000D+02, 1 APM.REQCTRLMODE = 1, 1 APM.RTOL = 0.1000000000000000D-05, 1 APM.SOLVER = 3, 1 APM.SOLVESTATUS = 1, 1 APM.SOLVETIME = 0.5155999999999999D+00, 1 APM.SPECS = 1, 1 APM.TIME_SHIFT = 0, 1 APM.WEB = 1, 1 APM.WEB_MENU = 1, 1 APM.WEB_REFRESH = 10, 1 FV(1).CRITICAL = 0, 0 FV(1).FSTATUS = 0.1000000000000000D+01, 0 FV(1).LSTVAL = 0.5000000000000000D+01, 1 FV(1).MEAS = 0.5000000000000000D+01, 1 FV(1).NEWVAL = 0.5000000000000000D+01, 1 FV(1).OSTATUS[1] = 0, 0 FV(1).OSTATUS[2] = 0, 0 FV(1).OSTATUSCHG[1] = 0, 0 FV(1).OSTATUSCHG[2] = 0, 0 FV(1).PSTATUS = 1, 0 FV(1).STATUS = 0, 0 FV(1).VDVL = 0.1000000000000000D+21, 0 FV(1).VLHI = 0.1000000000000000D+21, 0 FV(1).VLLO = -0.1000000000000000D+21, 0 MV(1).COST = 0.0000000000000000D+00, 0 MV(1).CRITICAL = 0, 0 MV(1).DCOST = 0.9999999747378752D-05, 0 MV(1).DMAX = 0.1000000000000000D+21, 0 MV(1).DMAXHI = 0.1000000000000000D+21, 0 MV(1).DMAXLO = -0.1000000000000000D+21, 0 MV(1).DPRED[1] = 0.0000000000000000D+00, 0 MV(1).FSTATUS = 0.1000000000000000D+01, 0 MV(1).LOWER = 0.1000000000000000D+01, 1 MV(1).LSTVAL = 0.2000000000000000D+01, 1 MV(1).MEAS = 0.2000000000000000D+01, 1 MV(1).MV_STEP_HOR = 0, 0 MV(1).NEWVAL = 0.2000000000000000D+01, 1 MV(1).NXTVAL = 0.2000000000000000D+01, 1 MV(1).OSTATUS[1] = 0, 0 MV(1).OSTATUS[2] = 0, 0 MV(1).OSTATUSCHG[1] = 0, 0 MV(1).OSTATUSCHG[2] = 0, 0 MV(1).PRED[0] = 0.2000000000000000D+01, 1 MV(1).PRED[1] = 0.2000000000000000D+01, 1 MV(1).PSTATUS = 1, 0 MV(1).REQONCTRL = 0, 0 MV(1).STATUS = 0, 0 MV(1).UPPER = 0.3000000000000000D+01, 1 MV(1).VDVL = 0.1000000000000000D+21, 0 MV(1).VLHI = 0.1000000000000000D+21, 0 MV(1).VLLO = -0.1000000000000000D+21, 0 CV(1).CRITICAL = 0, 0 CV(1).FSTATUS = 0.1000000000000000D+01, 0 CV(1).FDELAY = 0, 0 CV(1).LOWER = -0.1000000000000000D+21, 1 CV(1).LSTVAL = 0.5000000000000000D+01, 1 CV(1).MEAS = 0.1000000000000000D+01, 0 CV(1).MEAS_GAP = 0.1000000000000000D+01, 0 CV(1).MODEL = 0.5000000000000000D+01, 1 CV(1).OBJPCT = 0.0000000000000000D+00, 1 CV(1).OSTATUS[1] = 0, 0 CV(1).OSTATUS[2] = 0, 0 CV(1).OSTATUSCHG[1] = 0, 0 CV(1).OSTATUSCHG[2] = 0, 0 CV(1).PRED[0] = 0.5000000000000000D+01, 1 CV(1).PRED[1] = 0.5000000000000000D+01, 1 CV(1).PSTATUS = 1, 0 CV(1).UPPER = 0.1000000000000000D+21, 1 CV(1).VDVL = 0.1000000000000000D+21, 0 CV(1).VLHI = 0.1000000000000000D+21, 0 CV(1).VLLO = -0.1000000000000000D+21, 0 CV(1).WMEAS = 0.2000000000000000D+02, 0 CV(1).WMODEL = 0.2000000000000000D+01, 0
Options are stored in DBS files. When an option is changed with a call to apm_option, a line is added to the overrides.dbs file. When a measurement is recorded with apm_meas, a line is added to measurements.dbs.


Local options are associated only with parameters declared as Fixed Values (FVs) or Manipulated Variables (MVs) and variables declared as State Variables (SVs) or Controlled Variables (CVs). These options are not read when APM.DBS_READ? = 0 (OFF)''.
Local options are associated only with parameters declared as Fixed Values (FVs) or Manipulated Variables (MVs) and variables declared as State Variables (SVs) or Controlled Variables (CVs). These options are not read when APM.DBS_READ = 0 (OFF)''.


Certain options are associated only with parameters declared as Fixed Values (FVs) or Manipulated Variables (MVs) and variables declared as State Variables (SVs) or Controlled Variables (CVs). These options are not read when APM.DBS_READ = 0 (OFF).
Local options are associated only with parameters declared as Fixed Values (FVs) or Manipulated Variables (MVs) and variables declared as State Variables (SVs) or Controlled Variables (CVs). These options are not read when APM.DBS_READ? = 0 (OFF)''.


Certain options are associated only with variables declared as FV, MV, SV, or CV types. They are not read when APM.DBS_READ = 0 (OFF).
Certain options are associated only with parameters declared as Fixed Values (FVs) or Manipulated Variables (MVs) and variables declared as State Variables (SVs) or Controlled Variables (CVs). These options are not read when APM.DBS_READ = 0 (OFF).
- COST
- CRITICAL
- DCOST
- DMAX
- DMAXHI
- DMAXLO
- DPRED
- FSTATUS
- FDELAY
- LOWER
- LSTVAL
- MEAS
- MEAS_GAP
- MODEL
- MV_STEP_HOR
- NEWVAL
- NXTVAL
- OBJPCT
- OSTATUS
- OSTATUSCHG
- PRED
- PSTATUS
- REQONCTRL
- SP
- SPHI
- SPLO
- STATUS
- TAU
- TR_OPEN
- TR_INIT
- UPPER
- VDVL
- VLHI
- VLLO
- WMEAS
- WMODEL
- WSP
- WSPHI
- WSPLO
(:title Database File (DBS):)
(:title APMonitor Options Overview:)
- APM.APPINFO
- APM.APPINFOCHG
- APM.APPSTATUS
- APM.BNDS_CHK
- APM.COLDSTART
- APM.CSV_READ
- APM.CSV_WRITE
- APM.CTRLMODE
- APM.CTRL_HOR
- APM.CTRL_TIME
- APM.CTRL_UNITS
- APM.CV_TYPE
- APM.CV_WGT_SLOPE
- APM.CV_WGT_START
- APM.CYCLECOUNT
- APM.DBS_READ
- APM.DBS_WRITE
- APM.DIAGLEVEL
- APM.EV_TYPE
- APM.EV_WGT_SLOPE
- APM.HIST_HOR
- APM.HIST_UNITS
- APM.ICD_CALC
- APM.IMODE
- APM.ITERATIONS
- APM.MAX_ITER
- APM.MAX_TIME
- APM.MEAS_CHK
- APM.MV_DCOST_SLOPE
- APM.MV_STEP_HOR
- APM.MV_TYPE
- APM.NODES
- APM.OBJFCNVAL
- APM.OTOL
- APM.PRED_HOR
- APM.PRED_TIME
- APM.REQCTRLMODE
- APM.RTOL
- APM.SOLVESTATUS
- APM.SOLVER
- APM.SOLVETIME
- APM.SPECS
- APM.TIME_SHIFT
- APM.WEB
- APM.WEB_MENU
- APM.WEB_REFRESH
- APM.APPINFO
- APM.APPINFOCHG
- APM.APPSTATUS
- APM.AUTO_COLD
- APM.BAD_CYCLES
- APM.BNDS_CHK
- APM.COLDSTART
- APM.CSV_READ
- APM.CSV_WRITE
- APM.CTRL_HOR
- APM.CTRL_TIME
- APM.CTRL_UNITS
- APM.CTRLMODE
- APM.CV_WGT_SLOPE
- APM.CV_WGT_START
- APM.CV_TYPE
- APM.CYCLECOUNT
- APM.DBS_LEVEL
- APM.DBS_READ
- APM.DBS_WRITE
- APM.DIAGLEVEL
- APM.EV_WGT_SLOPE
- APM.EV_TYPE
- APM.FILTER
- APM.FRZE_CHK
- APM.HIST_HOR
- APM.HIST_UNITS
- APM.ICD_CALC
- APM.IMODE
- APM.ITERATIONS
- APM.LINEAR
- APM.MAX_ITER
- APM.MAX_MEMORY
- APM.MAX_TIME
- APM.MEAS_CHK
- APM.MV_DCOST_SLOPE
- APM.MV_STEP_HOR
- APM.MV_TYPE
- APM.NODES
- APM.OBJFCNVAL
- APM.OTOL
- APM.PRED_HOR
- APM.PRED_TIME
- APM.REDUCE
- APM.REPLAY
- APM.REQCTRLMODE
- APM.RTOL
- APM.SCALING
- APM.SENSITIVITY
- APM.SEQUENTIAL
- APM.SOLVER
- APM.SOLVESTATUS
- APM.SOLVETIME
- APM.SPECS
- APM.SPC_CHART
- APM.STREAM_LEVEL
- APM.TIME_SHIFT
- APM.WEB
- APM.WEB_MENU
- APM.WEB_REFRESH
- APM.WEB_PLOT_FREQ
SV(1).CRITICAL = 0, 0 SV(1).FSTATUS = 0.1000000000000000D+01, 0 SV(1).FDELAY = 0, 0 SV(1).LOWER = -0.1000000000000000D+21, 1 SV(1).LSTVAL = 0.5000000000000000D+01, 1 SV(1).MEAS = 0.1000000000000000D+01, 0 SV(1).MEAS_GAP = 0.1000000000000000D+01, 0 SV(1).MODEL = 0.5000000000000000D+01, 1 SV(1).OBJPCT = 0.0000000000000000D+00, 1 SV(1).OSTATUS[1] = 0, 0 SV(1).OSTATUS[2] = 0, 0 SV(1).OSTATUSCHG[1] = 0, 0 SV(1).OSTATUSCHG[2] = 0, 0 SV(1).PRED[0] = 0.5000000000000000D+01, 1 SV(1).PRED[1] = 0.5000000000000000D+01, 1 SV(1).PSTATUS = 1, 0 SV(1).UPPER = 0.1000000000000000D+21, 1 SV(1).VDVL = 0.1000000000000000D+21, 0 SV(1).VLHI = 0.1000000000000000D+21, 0 SV(1).VLLO = -0.1000000000000000D+21, 0 SV(1).WMEAS = 0.2000000000000000D+02, 0 SV(1).WMODEL = 0.2000000000000000D+01, 0
CV(1).CRITICAL = 0, 0 CV(1).FSTATUS = 0.1000000000000000D+01, 0 CV(1).FDELAY = 0, 0 CV(1).LOWER = -0.1000000000000000D+21, 1 CV(1).LSTVAL = 0.5000000000000000D+01, 1 CV(1).MEAS = 0.1000000000000000D+01, 0 CV(1).MEAS_GAP = 0.1000000000000000D+01, 0 CV(1).MODEL = 0.5000000000000000D+01, 1 CV(1).OBJPCT = 0.0000000000000000D+00, 1 CV(1).OSTATUS[1] = 0, 0 CV(1).OSTATUS[2] = 0, 0 CV(1).OSTATUSCHG[1] = 0, 0 CV(1).OSTATUSCHG[2] = 0, 0 CV(1).PRED[0] = 0.5000000000000000D+01, 1 CV(1).PRED[1] = 0.5000000000000000D+01, 1 CV(1).PSTATUS = 1, 0 CV(1).UPPER = 0.1000000000000000D+21, 1 CV(1).VDVL = 0.1000000000000000D+21, 0 CV(1).VLHI = 0.1000000000000000D+21, 0 CV(1).VLLO = -0.1000000000000000D+21, 0 CV(1).WMEAS = 0.2000000000000000D+02, 0 CV(1).WMODEL = 0.2000000000000000D+01, 0
DBS Parameters for Configuration
The configuration parameters before the model is parsed or data is input into the model structure. These parameters are read regardless of the value of APM.DBS_READ. When APM.DBS_READ = 0 (OFF) only the parameters associated with variables are skipped.
Global Application Options

FV, MV, SV, and CV Parameters
The variable parameters are associated only with variables declared in the INFO file. They are not read when APM.DBS_READ = 0 (OFF).
FV, MV, SV, and CV Options
Certain options are associated only with variables declared as FV, MV, SV, or CV types. They are not read when APM.DBS_READ = 0 (OFF).
Example File - test.dbs
Example DBS File
Options are stored in DBS files. When an option is changed with a call to apm_option, a line is added to the overrides.dbs file. When a measurement is recorded with apm_meas, a line is added to measurements.dbs. Below is an example of a DBS file with both global application options and options for individually classified parameters and variables.
DBS - Database File
The database file contains options and model inputs. The following is an exhaustive list of the configuration parameters for NLC type and FV, MV, SV, CV type. Each section (Global and Variables) includes an indication of the variable type (Integer or Real), the default value, data flow, and description.
(:title Database File (DBS):) (:keywords DBS, Database, Optimization, Estimation, Option, Configure, Default, Description:) (:description APMonitor stores options in a database file (DBS). They can be set from MATLAB or Python clients.:)
The database file contains options and model inputs. The following is an exhaustive list of the configuration parameters for APM type and FV, MV, SV, CV type. Each section (Global and Variables) includes an indication of the variable type (Integer or Real), the default value, data flow, and description.
The configuration parameters before the model is parsed or data is input into the model structure. These parameters are read regardless of the value of NLC.DBS_READ. When NLC.DBS_READ = 0 (OFF) only the parameters associated with variables are skipped.
- NLC.APPINFO
- NLC.APPINFOCHG
- NLC.APPSTATUS
- NLC.BNDS_CHK
- NLC.COLDSTART
- NLC.CSV_READ
- NLC.CSV_WRITE
- NLC.CTRLMODE
- NLC.CTRL_HOR
- NLC.CTRL_TIME
- NLC.CTRL_UNITS
- NLC.CV_TYPE
- NLC.CV_WGT_SLOPE
- NLC.CV_WGT_START
- NLC.CYCLECOUNT
- NLC.DBS_READ
- NLC.DBS_WRITE
- NLC.DIAGLEVEL
- NLC.EV_TYPE
- NLC.EV_WGT_SLOPE
- NLC.HIST_HOR
- NLC.HIST_UNITS
- NLC.ICD_CALC
- NLC.IMODE
- NLC.ITERATIONS
- NLC.MAX_ITER
- NLC.MAX_TIME
- NLC.MEAS_CHK
- NLC.MV_DCOST_SLOPE
- NLC.MV_STEP_HOR
- NLC.MV_TYPE
- NLC.NODES
- NLC.OBJFCNVAL
- NLC.OTOL
- NLC.PRED_HOR
- NLC.PRED_TIME
- NLC.REQCTRLMODE
- NLC.RTOL
- NLC.SOLVESTATUS
- NLC.SOLVER
- NLC.SOLVETIME
- NLC.SPECS
- NLC.TIME_SHIFT
- NLC.WEB
- NLC.WEB_MENU
- NLC.WEB_REFRESH
The configuration parameters before the model is parsed or data is input into the model structure. These parameters are read regardless of the value of APM.DBS_READ. When APM.DBS_READ = 0 (OFF) only the parameters associated with variables are skipped.
- APM.APPINFO
- APM.APPINFOCHG
- APM.APPSTATUS
- APM.BNDS_CHK
- APM.COLDSTART
- APM.CSV_READ
- APM.CSV_WRITE
- APM.CTRLMODE
- APM.CTRL_HOR
- APM.CTRL_TIME
- APM.CTRL_UNITS
- APM.CV_TYPE
- APM.CV_WGT_SLOPE
- APM.CV_WGT_START
- APM.CYCLECOUNT
- APM.DBS_READ
- APM.DBS_WRITE
- APM.DIAGLEVEL
- APM.EV_TYPE
- APM.EV_WGT_SLOPE
- APM.HIST_HOR
- APM.HIST_UNITS
- APM.ICD_CALC
- APM.IMODE
- APM.ITERATIONS
- APM.MAX_ITER
- APM.MAX_TIME
- APM.MEAS_CHK
- APM.MV_DCOST_SLOPE
- APM.MV_STEP_HOR
- APM.MV_TYPE
- APM.NODES
- APM.OBJFCNVAL
- APM.OTOL
- APM.PRED_HOR
- APM.PRED_TIME
- APM.REQCTRLMODE
- APM.RTOL
- APM.SOLVESTATUS
- APM.SOLVER
- APM.SOLVETIME
- APM.SPECS
- APM.TIME_SHIFT
- APM.WEB
- APM.WEB_MENU
- APM.WEB_REFRESH
The variable parameters are associated only with variables declared in the INFO file. They are not read when NLC.DBS_READ = 0 (OFF).
The variable parameters are associated only with variables declared in the INFO file. They are not read when APM.DBS_READ = 0 (OFF).
(:table border=1 width=50% align=left bgcolor=#EEEEEE cellspacing=0:) (:cellnr:)
DB_Variables NLC.APPINFO = 0, 1, NONE NLC.APPINFOCHG = 0, 1, NONE NLC.APPSTATUS = 1, 1, NONE NLC.BNDS_CHK = 1, 1, NONE NLC.COLDSTART = 0, 1, NONE NLC.CSV_READ = 0, 1, NONE NLC.CSV_WRITE = 0, 1, NONE NLC.CTRL_HOR = 1, 1, NONE NLC.CTRL_TIME = 0.6000000000000000D+02, 1, NONE NLC.CTRL_UNITS = 1, 1, NONE NLC.CTRLMODE = 1, 1, NONE NLC.CV_WGT_SLOPE = 0.0000000000000000D+00, 1, NONE NLC.CV_WGT_START = 0, 1, NONE NLC.CV_TYPE = 1, 1, NONE NLC.CYCLECOUNT = 70, 1, NONE NLC.DBS_READ = 0, 1, NONE NLC.DBS_WRITE = 1, 1, NONE NLC.DIAGLEVEL = 0, 1, NONE NLC.EV_WGT_SLOPE = 0.0000000000000000D+00, 1, NONE NLC.EV_TYPE = 2, 1, NONE NLC.HIST_HOR = 0, 1, NONE NLC.HIST_UNITS = 0, 1, NONE NLC.ICD_CALC = 0, 1, NONE NLC.IMODE = 3, 1, NONE NLC.ITERATIONS = 0, 1, NONE NLC.MAX_ITER = 25, 1, NONE NLC.MAX_TIME = 0.1000000000000000D+21, 1, NONE NLC.MEAS_CHK = 1, 1, NONE NLC.MV_DCOST_SLOPE = 0.1000000000000000D+00, 1, NONE NLC.MV_STEP_HOR = 1, 1, NONE NLC.MV_TYPE = 0, 1, NONE NLC.NODES = 4, 1, NONE NLC.OBJFCNVAL = 0.0000000000000000D+00, 1, NONE NLC.OTOL = 0.1000000000000000D-05, 1, NONE NLC.PRED_HOR = 3, 1, NONE NLC.PRED_TIME = 0.6000000000000000D+02, 1, NONE NLC.REQCTRLMODE = 1, 1, NONE NLC.RTOL = 0.1000000000000000D-05, 1, NONE NLC.SOLVER = 3, 1, NONE NLC.SOLVESTATUS = 1, 1, NONE NLC.SOLVETIME = 0.5155999999999999D+00, 1, NONE NLC.SPECS = 1, 1, NONE NLC.TIME_SHIFT = 0, 1, NONE NLC.WEB = 1, 1, NONE NLC.WEB_MENU = 1, 1, NONE NLC.WEB_REFRESH = 10, 1, NONE FV(1).CRITICAL = 0, 0, NONE FV(1).FSTATUS = 0.1000000000000000D+01, 0, NONE FV(1).LSTVAL = 0.5000000000000000D+01, 1, NONE FV(1).MEAS = 0.5000000000000000D+01, 1, NONE FV(1).NEWVAL = 0.5000000000000000D+01, 1, NONE FV(1).OSTATUS[1] = 0, 0, NONE FV(1).OSTATUS[2] = 0, 0, NONE FV(1).OSTATUSCHG[1] = 0, 0, NONE FV(1).OSTATUSCHG[2] = 0, 0, NONE FV(1).PSTATUS = 1, 0, NONE FV(1).STATUS = 0, 0, NONE FV(1).VDVL = 0.1000000000000000D+21, 0, NONE FV(1).VLHI = 0.1000000000000000D+21, 0, NONE FV(1).VLLO = -0.1000000000000000D+21, 0, NONE MV(1).COST = 0.0000000000000000D+00, 0, NONE MV(1).CRITICAL = 0, 0, NONE MV(1).DCOST = 0.9999999747378752D-05, 0, NONE MV(1).DMAX = 0.1000000000000000D+21, 0, NONE MV(1).DMAXHI = 0.1000000000000000D+21, 0, NONE MV(1).DMAXLO = -0.1000000000000000D+21, 0, NONE MV(1).DPRED[1] = 0.0000000000000000D+00, 0, NONE MV(1).FSTATUS = 0.1000000000000000D+01, 0, NONE MV(1).LOWER = 0.1000000000000000D+01, 1, NONE MV(1).LSTVAL = 0.2000000000000000D+01, 1, NONE MV(1).MEAS = 0.2000000000000000D+01, 1, NONE MV(1).MV_STEP_HOR = 0, 0, NONE MV(1).NEWVAL = 0.2000000000000000D+01, 1, NONE MV(1).NXTVAL = 0.2000000000000000D+01, 1, NONE MV(1).OSTATUS[1] = 0, 0, NONE MV(1).OSTATUS[2] = 0, 0, NONE MV(1).OSTATUSCHG[1] = 0, 0, NONE MV(1).OSTATUSCHG[2] = 0, 0, NONE MV(1).PRED[0] = 0.2000000000000000D+01, 1, NONE MV(1).PRED[1] = 0.2000000000000000D+01, 1, NONE MV(1).PSTATUS = 1, 0, NONE MV(1).REQONCTRL = 0, 0, NONE MV(1).STATUS = 0, 0, NONE MV(1).UPPER = 0.3000000000000000D+01, 1, NONE MV(1).VDVL = 0.1000000000000000D+21, 0, NONE MV(1).VLHI = 0.1000000000000000D+21, 0, NONE MV(1).VLLO = -0.1000000000000000D+21, 0, NONE SV(1).CRITICAL = 0, 0, NONE SV(1).FSTATUS = 0.1000000000000000D+01, 0, NONE SV(1).FDELAY = 0, 0, NONE SV(1).LOWER = -0.1000000000000000D+21, 1, NONE SV(1).LSTVAL = 0.5000000000000000D+01, 1, NONE SV(1).MEAS = 0.1000000000000000D+01, 0, NONE SV(1).MEAS_GAP = 0.1000000000000000D+01, 0, NONE SV(1).MODEL = 0.5000000000000000D+01, 1, NONE SV(1).OBJPCT = 0.0000000000000000D+00, 1, NONE SV(1).OSTATUS[1] = 0, 0, NONE SV(1).OSTATUS[2] = 0, 0, NONE SV(1).OSTATUSCHG[1] = 0, 0, NONE SV(1).OSTATUSCHG[2] = 0, 0, NONE SV(1).PRED[0] = 0.5000000000000000D+01, 1, NONE SV(1).PRED[1] = 0.5000000000000000D+01, 1, NONE SV(1).PSTATUS = 1, 0, NONE SV(1).UPPER = 0.1000000000000000D+21, 1, NONE SV(1).VDVL = 0.1000000000000000D+21, 0, NONE SV(1).VLHI = 0.1000000000000000D+21, 0, NONE SV(1).VLLO = -0.1000000000000000D+21, 0, NONE SV(1).WMEAS = 0.2000000000000000D+02, 0, NONE SV(1).WMODEL = 0.2000000000000000D+01, 0, NONE End DB_Variables
(:tableend:)
APM.APPINFO = 0, 1 APM.APPINFOCHG = 0, 1 APM.APPSTATUS = 1, 1 APM.BNDS_CHK = 1, 1 APM.COLDSTART = 0, 1 APM.CSV_READ = 0, 1 APM.CSV_WRITE = 0, 1 APM.CTRL_HOR = 1, 1 APM.CTRL_TIME = 0.6000000000000000D+02, 1 APM.CTRL_UNITS = 1, 1 APM.CTRLMODE = 1, 1 APM.CV_WGT_SLOPE = 0.0000000000000000D+00, 1 APM.CV_WGT_START = 0, 1 APM.CV_TYPE = 1, 1 APM.CYCLECOUNT = 70, 1 APM.DBS_READ = 0, 1 APM.DBS_WRITE = 1, 1 APM.DIAGLEVEL = 0, 1 APM.EV_WGT_SLOPE = 0.0000000000000000D+00, 1 APM.EV_TYPE = 2, 1 APM.HIST_HOR = 0, 1 APM.HIST_UNITS = 0, 1 APM.ICD_CALC = 0, 1 APM.IMODE = 3, 1 APM.ITERATIONS = 0, 1 APM.MAX_ITER = 25, 1 APM.MAX_TIME = 0.1000000000000000D+21, 1 APM.MEAS_CHK = 1, 1 APM.MV_DCOST_SLOPE = 0.1000000000000000D+00, 1 APM.MV_STEP_HOR = 1, 1 APM.MV_TYPE = 0, 1 APM.NODES = 4, 1 APM.OBJFCNVAL = 0.0000000000000000D+00, 1 APM.OTOL = 0.1000000000000000D-05, 1 APM.PRED_HOR = 3, 1 APM.PRED_TIME = 0.6000000000000000D+02, 1 APM.REQCTRLMODE = 1, 1 APM.RTOL = 0.1000000000000000D-05, 1 APM.SOLVER = 3, 1 APM.SOLVESTATUS = 1, 1 APM.SOLVETIME = 0.5155999999999999D+00, 1 APM.SPECS = 1, 1 APM.TIME_SHIFT = 0, 1 APM.WEB = 1, 1 APM.WEB_MENU = 1, 1 APM.WEB_REFRESH = 10, 1 FV(1).CRITICAL = 0, 0 FV(1).FSTATUS = 0.1000000000000000D+01, 0 FV(1).LSTVAL = 0.5000000000000000D+01, 1 FV(1).MEAS = 0.5000000000000000D+01, 1 FV(1).NEWVAL = 0.5000000000000000D+01, 1 FV(1).OSTATUS[1] = 0, 0 FV(1).OSTATUS[2] = 0, 0 FV(1).OSTATUSCHG[1] = 0, 0 FV(1).OSTATUSCHG[2] = 0, 0 FV(1).PSTATUS = 1, 0 FV(1).STATUS = 0, 0 FV(1).VDVL = 0.1000000000000000D+21, 0 FV(1).VLHI = 0.1000000000000000D+21, 0 FV(1).VLLO = -0.1000000000000000D+21, 0 MV(1).COST = 0.0000000000000000D+00, 0 MV(1).CRITICAL = 0, 0 MV(1).DCOST = 0.9999999747378752D-05, 0 MV(1).DMAX = 0.1000000000000000D+21, 0 MV(1).DMAXHI = 0.1000000000000000D+21, 0 MV(1).DMAXLO = -0.1000000000000000D+21, 0 MV(1).DPRED[1] = 0.0000000000000000D+00, 0 MV(1).FSTATUS = 0.1000000000000000D+01, 0 MV(1).LOWER = 0.1000000000000000D+01, 1 MV(1).LSTVAL = 0.2000000000000000D+01, 1 MV(1).MEAS = 0.2000000000000000D+01, 1 MV(1).MV_STEP_HOR = 0, 0 MV(1).NEWVAL = 0.2000000000000000D+01, 1 MV(1).NXTVAL = 0.2000000000000000D+01, 1 MV(1).OSTATUS[1] = 0, 0 MV(1).OSTATUS[2] = 0, 0 MV(1).OSTATUSCHG[1] = 0, 0 MV(1).OSTATUSCHG[2] = 0, 0 MV(1).PRED[0] = 0.2000000000000000D+01, 1 MV(1).PRED[1] = 0.2000000000000000D+01, 1 MV(1).PSTATUS = 1, 0 MV(1).REQONCTRL = 0, 0 MV(1).STATUS = 0, 0 MV(1).UPPER = 0.3000000000000000D+01, 1 MV(1).VDVL = 0.1000000000000000D+21, 0 MV(1).VLHI = 0.1000000000000000D+21, 0 MV(1).VLLO = -0.1000000000000000D+21, 0 SV(1).CRITICAL = 0, 0 SV(1).FSTATUS = 0.1000000000000000D+01, 0 SV(1).FDELAY = 0, 0 SV(1).LOWER = -0.1000000000000000D+21, 1 SV(1).LSTVAL = 0.5000000000000000D+01, 1 SV(1).MEAS = 0.1000000000000000D+01, 0 SV(1).MEAS_GAP = 0.1000000000000000D+01, 0 SV(1).MODEL = 0.5000000000000000D+01, 1 SV(1).OBJPCT = 0.0000000000000000D+00, 1 SV(1).OSTATUS[1] = 0, 0 SV(1).OSTATUS[2] = 0, 0 SV(1).OSTATUSCHG[1] = 0, 0 SV(1).OSTATUSCHG[2] = 0, 0 SV(1).PRED[0] = 0.5000000000000000D+01, 1 SV(1).PRED[1] = 0.5000000000000000D+01, 1 SV(1).PSTATUS = 1, 0 SV(1).UPPER = 0.1000000000000000D+21, 1 SV(1).VDVL = 0.1000000000000000D+21, 0 SV(1).VLHI = 0.1000000000000000D+21, 0 SV(1).VLLO = -0.1000000000000000D+21, 0 SV(1).WMEAS = 0.2000000000000000D+02, 0 SV(1).WMODEL = 0.2000000000000000D+01, 0
The database file contains options and model inputs. The following is an exhaustive list of the configuration parameters for NLC type and FV, MV, SV, CV type. Each section includes an indication of the variable type (Integer or Real), the default value, data flow, and description.
The database file contains options and model inputs. The following is an exhaustive list of the configuration parameters for NLC type and FV, MV, SV, CV type. Each section (Global and Variables) includes an indication of the variable type (Integer or Real), the default value, data flow, and description.
(:table border=1 width=50% align=left bgcolor=#EEEEEE cellspacing=0:) (:cellnr:)
(:tableend:)
Example File - test.dbs
DB_Variables NLC.APPINFO = 0, 1, NONE NLC.APPINFOCHG = 0, 1, NONE NLC.APPSTATUS = 1, 1, NONE NLC.BNDS_CHK = 1, 1, NONE NLC.COLDSTART = 0, 1, NONE NLC.CSV_READ = 0, 1, NONE NLC.CSV_WRITE = 0, 1, NONE NLC.CTRL_HOR = 1, 1, NONE NLC.CTRL_TIME = 0.6000000000000000D+02, 1, NONE NLC.CTRL_UNITS = 1, 1, NONE NLC.CTRLMODE = 1, 1, NONE NLC.CV_WGT_SLOPE = 0.0000000000000000D+00, 1, NONE NLC.CV_WGT_START = 0, 1, NONE NLC.CV_TYPE = 1, 1, NONE NLC.CYCLECOUNT = 70, 1, NONE NLC.DBS_READ = 0, 1, NONE NLC.DBS_WRITE = 1, 1, NONE NLC.DIAGLEVEL = 0, 1, NONE NLC.EV_WGT_SLOPE = 0.0000000000000000D+00, 1, NONE NLC.EV_TYPE = 2, 1, NONE NLC.HIST_HOR = 0, 1, NONE NLC.HIST_UNITS = 0, 1, NONE NLC.ICD_CALC = 0, 1, NONE NLC.IMODE = 3, 1, NONE NLC.ITERATIONS = 0, 1, NONE NLC.MAX_ITER = 25, 1, NONE NLC.MAX_TIME = 0.1000000000000000D+21, 1, NONE NLC.MEAS_CHK = 1, 1, NONE NLC.MV_DCOST_SLOPE = 0.1000000000000000D+00, 1, NONE NLC.MV_STEP_HOR = 1, 1, NONE NLC.MV_TYPE = 0, 1, NONE NLC.NODES = 4, 1, NONE NLC.OBJFCNVAL = 0.0000000000000000D+00, 1, NONE NLC.OTOL = 0.1000000000000000D-05, 1, NONE NLC.PRED_HOR = 3, 1, NONE NLC.PRED_TIME = 0.6000000000000000D+02, 1, NONE NLC.REQCTRLMODE = 1, 1, NONE NLC.RTOL = 0.1000000000000000D-05, 1, NONE NLC.SOLVER = 3, 1, NONE NLC.SOLVESTATUS = 1, 1, NONE NLC.SOLVETIME = 0.5155999999999999D+00, 1, NONE NLC.SPECS = 1, 1, NONE NLC.TIME_SHIFT = 0, 1, NONE NLC.WEB = 1, 1, NONE NLC.WEB_MENU = 1, 1, NONE NLC.WEB_REFRESH = 10, 1, NONE FV(1).CRITICAL = 0, 0, NONE FV(1).FSTATUS = 0.1000000000000000D+01, 0, NONE FV(1).LSTVAL = 0.5000000000000000D+01, 1, NONE FV(1).MEAS = 0.5000000000000000D+01, 1, NONE FV(1).NEWVAL = 0.5000000000000000D+01, 1, NONE FV(1).OSTATUS[1] = 0, 0, NONE FV(1).OSTATUS[2] = 0, 0, NONE FV(1).OSTATUSCHG[1] = 0, 0, NONE FV(1).OSTATUSCHG[2] = 0, 0, NONE FV(1).PSTATUS = 1, 0, NONE FV(1).STATUS = 0, 0, NONE FV(1).VDVL = 0.1000000000000000D+21, 0, NONE FV(1).VLHI = 0.1000000000000000D+21, 0, NONE FV(1).VLLO = -0.1000000000000000D+21, 0, NONE MV(1).COST = 0.0000000000000000D+00, 0, NONE MV(1).CRITICAL = 0, 0, NONE MV(1).DCOST = 0.9999999747378752D-05, 0, NONE MV(1).DMAX = 0.1000000000000000D+21, 0, NONE MV(1).DMAXHI = 0.1000000000000000D+21, 0, NONE MV(1).DMAXLO = -0.1000000000000000D+21, 0, NONE MV(1).DPRED[1] = 0.0000000000000000D+00, 0, NONE MV(1).FSTATUS = 0.1000000000000000D+01, 0, NONE MV(1).LOWER = 0.1000000000000000D+01, 1, NONE MV(1).LSTVAL = 0.2000000000000000D+01, 1, NONE MV(1).MEAS = 0.2000000000000000D+01, 1, NONE MV(1).MV_STEP_HOR = 0, 0, NONE MV(1).NEWVAL = 0.2000000000000000D+01, 1, NONE MV(1).NXTVAL = 0.2000000000000000D+01, 1, NONE MV(1).OSTATUS[1] = 0, 0, NONE MV(1).OSTATUS[2] = 0, 0, NONE MV(1).OSTATUSCHG[1] = 0, 0, NONE MV(1).OSTATUSCHG[2] = 0, 0, NONE MV(1).PRED[0] = 0.2000000000000000D+01, 1, NONE MV(1).PRED[1] = 0.2000000000000000D+01, 1, NONE MV(1).PSTATUS = 1, 0, NONE MV(1).REQONCTRL = 0, 0, NONE MV(1).STATUS = 0, 0, NONE MV(1).UPPER = 0.3000000000000000D+01, 1, NONE MV(1).VDVL = 0.1000000000000000D+21, 0, NONE MV(1).VLHI = 0.1000000000000000D+21, 0, NONE MV(1).VLLO = -0.1000000000000000D+21, 0, NONE SV(1).CRITICAL = 0, 0, NONE SV(1).FSTATUS = 0.1000000000000000D+01, 0, NONE SV(1).FDELAY = 0, 0, NONE SV(1).LOWER = -0.1000000000000000D+21, 1, NONE SV(1).LSTVAL = 0.5000000000000000D+01, 1, NONE SV(1).MEAS = 0.1000000000000000D+01, 0, NONE SV(1).MEAS_GAP = 0.1000000000000000D+01, 0, NONE SV(1).MODEL = 0.5000000000000000D+01, 1, NONE SV(1).OBJPCT = 0.0000000000000000D+00, 1, NONE SV(1).OSTATUS[1] = 0, 0, NONE SV(1).OSTATUS[2] = 0, 0, NONE SV(1).OSTATUSCHG[1] = 0, 0, NONE SV(1).OSTATUSCHG[2] = 0, 0, NONE SV(1).PRED[0] = 0.5000000000000000D+01, 1, NONE SV(1).PRED[1] = 0.5000000000000000D+01, 1, NONE SV(1).PSTATUS = 1, 0, NONE SV(1).UPPER = 0.1000000000000000D+21, 1, NONE SV(1).VDVL = 0.1000000000000000D+21, 0, NONE SV(1).VLHI = 0.1000000000000000D+21, 0, NONE SV(1).VLLO = -0.1000000000000000D+21, 0, NONE SV(1).WMEAS = 0.2000000000000000D+02, 0, NONE SV(1).WMODEL = 0.2000000000000000D+01, 0, NONE End DB_Variables
- COST
- CRITICAL
- DCOST
- DMAX
- DMAXHI
- DMAXLO
- DPRED
- FSTATUS
- FDELAY
- LOWER
- LSTVAL
- MEAS
- MEAS_GAP
- MODEL
- MV_STEP_HOR
- NEWVAL
- NXTVAL
- OBJPCT
- OSTATUS
- OSTATUSCHG
- PRED
- PSTATUS
- REQONCTRL
- SP
- SPHI
- SPLO
- STATUS
- TAU
- TR_OPEN
- TR_INIT UPPER
- VDVL
- VLHI
- VLLO
- WMEAS
- WMODEL
- WSP
- WSPHI
- WSPLO
COST
Type: Real Default Value: 0.0 Data Flow: Input Description: Cost weight: (+)=minimize, (-)=maximize
CRITICAL
Type: Integer Default Value: 0 Data Flow: Input Description: Critical: 0=OFF, 1=ON'
DCOST
Type: Real Default Value: 0.00001 Data Flow: Input Description: Delta cost penalty for MV movement
DMAX
Type: Real Default Value: 1.0e20 Data Flow: Input Description: Delta MV maximum step per horizon interval
DMAXHI
Type: Real Default Value: 1.0e20 Data Flow: Input Description: Delta MV positive maximum step per horizon interval
DMAXLO
Type: Real Default Value: -1.0e20 Data Flow: Input Description: Delta MV negative maximum step per horizon interval
DPRED
Type: Real Default Value: 0.0 Data Flow: Output Description: Delta prediction changes for each step'
FSTATUS
Type: Real Default Value: 1.0 Data Flow: Input Description: Feedback status: 1=ON, 0=OFF
FDELAY
Type: Integer Default Value: 0 Data Flow: Input Description: Feedback delay: 0=No Delay, >=1 horizon steps for delay
LOWER
Type: Real Default Value: -1.0e20 Data Flow: Input Description: Lower bound
LSTVAL
Type: Real Default Value: 1.0 Data Flow: Output Description: Last value from previous solution
MEAS
Type: Real Default Value: 1.0 Data Flow: Input Description: Measured value
MEAS_GAP
Type: Real Default Value: 1.0 Data Flow: Input Description: Deadband for noise rejection of measurements in MHE
MODEL
Type: Real Default Value: 1.0 Data Flow: Output Description: Model predicted value
MV_STEP_HOR
Type: Integer Default Value: 1 (for NLC.MV_STEP_HOR) or 0 (for MV(#).MV_STEP_HOR) Data Flow: Input Description: Step length for manipulated variables: 0 uses NLC.MV_STEP_HOR as default
NEWVAL
Type: Real Default Value: 1.0 Data Flow: Output Description: New value implemented by the estimator or controller (NEWVAL = MEAS when not in control)
NXTVAL
Type: Real Default Value: 1.0 Data Flow: Output Description: Next value that the estimator or controller would implement were it on
OBJPCT
Type: Real Default Value: 0.0 Data Flow: Output Description: Percent of objective function contibution considering all SV and CV variables
OSTATUS
Type: Integer Default Value: 0 Data Flow: Input and Output Description: Bit encoding for status messages
OSTATUSCHG
Type: Integer Default Value: 0 Data Flow: Input Description: Change in bit encoding for status messages
PRED
Type: Real Default Value: 1.0 Data Flow: Output Description: Prediction horizon
PSTATUS
Type: Integer Default Value: 1 Data Flow: Input Description: Instrument status: 1=GOOD, 0=BAD
REQONCTRL
Type: Integer Default Value: 0 Data Flow: Input Description: Required for control mode to be ON (3): 1=ON, 0=OFF
SP
Type: Real Default Value: 0.0 Data Flow: Input Description: Set point for squared error model
SPHI
Type: Real Default Value: 1.0e20 Data Flow: Input Description: Set point high for linear error model
SPLO
Type: Real Default Value: -1.0e20 Data Flow: Input Description: Set point low for linear error model
STATUS
Type: Integer Default Value: 0 Data Flow: Input Description: Status: 1=ON, 0=OFF
TAU
Type: Real Default Value: 60.0 Data Flow: Input Description: Time constant for controlled variable response
TR_OPEN
Type: Real Default Value: 1.0 Data Flow: Input Description: Initial trajectory opening ratio (0=ref traj, 1=tunnel, 2=funnel)
TR_INIT
Type: Integer Type: Real Default Value: 1 Data Flow: Input Description: Traj initialization (0=dead-band, 1=re-center with coldstart/out-of-service, 2=re-center always)
UPPER
Type: Real Default Value: 1.0e20 Data Flow: Input Description: Upper bound
VDVL
Type: Real Default Value: 1.0e20 Data Flow: Input Description: Delta validity limit
VLHI
Type: Real Default Value: 1.0e20 Data Flow: Input Description: Upper validity limit
VLLO
Type: Real Default Value: -1.0e20 Data Flow: Input Description: Lower validity limit
WMEAS
Type: Real Default Value: 20.0 Data Flow: Input Description: Objective function weight on measured value
WMODEL
Type: Real Default Value: 2.0d0 Data Flow: Input Description: Objective function weight on model value
WSP
Type: Real Default Value: 1.0 Data Flow: Input Description: Objective function weight on set point for squared error model
WSPHI
Type: Real Default Value: 1.0 Data Flow: Input Description: Objective function weight on upper set point for linear error model
WSPLO
Type: Real Default Value: 1.0 Data Flow: Input Description: Objective function weight on lower set point for linear error model
NLC.APPINFO
Type: Integer Default Value: 0 Data Flow: Input and Output Description: Application information: 0=good, error otherwise
NLC.APPINFOCHG
Type: Integer Default Value: 0 Data Flow: Output Description: Application information change (new-old): 0=no change
NLC.APPSTATUS
Type: Integer Default Value: 1 Data Flow: Output Description: Application status: 1=good, 0=bad
NLC.BNDS_CHK
Type: Integer Default Value: 1 Data Flow: Input Description: Bounds checking: 1=ON, 0=OFF
NLC.COLDSTART
Type: Integer Default Value: 0 Data Flow: Input and Output Description: Cold start model: 0=warm start, 1=cold start
NLC.CSV_READ
Type: Integer Default Value: 0 Data Flow: Input Description: CSV read: 0=Off, 1=Batch, 2=Sequential
NLC.CSV_WRITE
Type: Integer Default Value: 0 Data Flow: Input Description: CSV write: 0=Off, 1=On
NLC.CTRLMODE
Type: Integer Default Value: 1 Data Flow: Output Description: Control mode: 1=simulate, 2=predict, 3=control
NLC.CTRL_HOR
Type: Integer Default Value: 1 Data Flow: Input Description: Control horizon: Horizon length where MVs can be adjusted by the solver
NLC.CTRL_TIME
Type: Real Default Value: 60 Data Flow: Input Description: Time for each step in the control horizon
NLC.CTRL_UNITS
Type: Integer Default Value: 1 Data Flow: Input Description: Model time units (1=sec, 2=min, 3=hrs, 4=days, 5=yrs)
NLC.CV_TYPE
Type: Integer Default Value: 1 Data Flow: Input Description: Controlled variable error model type: 1=linear, 2=squared, 3=ref traj
NLC.CV_WGT_SLOPE
Type: Real Default Value: 0.0 Data Flow: Input Description: Slope for weight on future CV error (e.g. [+] favors steady state)
NLC.CV_WGT_START
Type: Integer Default Value: 0 Data Flow: Input Description: Start interval for controlled variable error model weights
NLC.CYCLECOUNT
Type: Integer Default Value: 0 Data Flow: Input and Output Description: Cycle count, increments every cycle
NLC.DBS_READ
Type: Integer Default Value: 1 Data Flow: Input Description: Database read: 1=ON, 0=OFF
NLC.DBS_WRITE
Type: Integer Default Value: 1 Data Flow: Input Description: Database write: 1=ON, 0=OFF
NLC.DIAGLEVEL
Type: Integer Default Value: 0 Data Flow: Input Description: Diagnostic level: 0=none, 1=messages, 2=file checkpoints, 4=diagnostic files, 5=check 1st deriv
NLC.EV_TYPE
Type: Integer Default Value: 1 Data Flow: Input Description: Estimated variable error model type: 1=linear, 2=squared, 3=approximate linear
NLC.EV_WGT_SLOPE
Type: Real Default Value: 0.0 Data Flow: Input Description: Slope for weight on more cuurent EV error (e.g. favor near-term matching)
NLC.HIST_HOR
Type: Integer Default Value: 0 Data Flow: Input Description: History horizon (SIM and CTL only): Integer >= 0
NLC.HIST_UNITS
Type: Integer Default Value: 0 Data Flow: Input Description: History time units on plots only (0=same as CTRL_UNITS, 1=sec, 2=min, 3=hrs, 4=days, 5=yrs)
NLC.ICD_CALC
Type: Integer Default Value: 0 Data Flow: Input Description: Specifications for initial condition differentials (MHE only): 0=OFF, 1=ON
NLC.IMODE
Type: Integer Default Value: 3 Data Flow: Input Description: Model solution mode: 1=ss, 2=mpu, 3=rto, 4=sim, 5=est, 6=ctl
NLC.ITERATIONS
Type: Integer Default Value: 1 Data Flow: Output Description: Iterations for solution: >=1
NLC.MAX_ITER
Type: Integer Default Value: 25 Data Flow: Input Description: Maximum iteration: >=1
NLC.MAX_TIME
Type: Real Default Value: 1.0e20 Data Flow: Input Description: Maximum run time in seconds
NLC.MEAS_CHK
Type: Integer Default Value: 1 Data Flow: Input Description: Measurement checking: 1=ON, 0=OFF
NLC.MV_DCOST_SLOPE
Type: Real Default Value: 0.1d0 Data Flow: Input Description: Slope for penalization on future MV moves (i.e. reduces controller procrastination)
NLC.MV_STEP_HOR
Type: Integer Default Value: 1 (for NLC.MV_STEP_HOR) or 0 (for MV(#).MV_STEP_HOR) Data Flow: Input Description: Step length for manipulated variables: 0 uses NLC.MV_STEP_HOR as default
NLC.MV_TYPE
Type: Integer Default Value: 0 Data Flow: Input Description: Manipulated variable type: 0=zero order hold, 1=linear
NLC.NODES
Type: Integer Default Value: 4 Data Flow: Input Description: Nodes in each horizon step
NLC.OBJFCNVAL
Type: Real Default Value: 0.0 Data Flow: Output Description: Objective function value
NLC.OTOL
Type: Real Default Value: 1.0e-6 Data Flow: Input Description: Objective function tolerance for successful solution
NLC.PRED_HOR
Type: Integer Default Value: 1.0 Data Flow: Input Description: Prediction horizon: Total horizon, including control horizon
NLC.PRED_TIME
Type: Real Default Value: 60.0 Data Flow: Input Description: Time for each step in the horizon
NLC.REQCTRLMODE
Type: Integer Default Value: 1 Data Flow: Input Description: Requested control mode: 1=simulate, 2=predict, 3=control
NLC.RTOL
Type: Real Default Value: 1.0e-6 Data Flow: Input Description: Equation solution tolerance
NLC.SOLVESTATUS
Type: Integer Default Value: 1 Data Flow: Output Description: Solution solve status: 1=good
NLC.SOLVER
Type: Integer Default Value: 3 Data Flow: Input Description: Solver options: 1=NOVA, 2=IPOPT-v2.3, 3=IPOPT-v3.5, 4=SNOPT, 5=MINOS
NLC.SOLVETIME
Type: Real Default Value: 1.0 Data Flow: Output Description: Solution time (seconds)
NLC.SPECS
Type: Integer Default Value: 1 Data Flow: Input Description: Secifications from restart file: 1=ON, 0=OFF
NLC.TIME_SHIFT
Type: Integer Default Value: 1 Data Flow: Input Description: Time shift for dynamic problems: 1=ON, 0=OFF
NLC.WEB
Type: Integer Default Value: 1 Data Flow: Input Description: Generate HTML pages: 1=ON, 0=OFF
NLC.WEB_MENU
Type: Integer Default Value: 1 Data Flow: Input Description: Generate HTML navigation menus: 1=ON, 0=OFF
NLC.WEB_REFRESH
Type: Integer Default Value: 10 Data Flow: Input Description: Automatic refresh rate on HTML pages (default 10 minutes)
- NLC.APPINFO
- NLC.APPINFOCHG
- NLC.APPSTATUS
- NLC.BNDS_CHK
- NLC.COLDSTART
- NLC.CSV_READ
- NLC.CSV_WRITE
- NLC.CTRLMODE
- NLC.CTRL_HOR
- NLC.CTRL_TIME
- NLC.CTRL_UNITS
- NLC.CV_TYPE
- NLC.CV_WGT_SLOPE
- NLC.CV_WGT_START
- NLC.CYCLECOUNT
- NLC.DBS_READ
- NLC.DBS_WRITE
- NLC.DIAGLEVEL
- NLC.EV_TYPE
- NLC.EV_WGT_SLOPE
- NLC.HIST_HOR
- NLC.HIST_UNITS
- NLC.ICD_CALC
- NLC.IMODE
- NLC.ITERATIONS
- NLC.MAX_ITER
- NLC.MAX_TIME
- NLC.MEAS_CHK
- NLC.MV_DCOST_SLOPE
- NLC.MV_STEP_HOR
- NLC.MV_TYPE
- NLC.NODES
- NLC.OBJFCNVAL
- NLC.OTOL
- NLC.PRED_HOR
- NLC.PRED_TIME
- NLC.REQCTRLMODE
- NLC.RTOL
- NLC.SOLVESTATUS
- NLC.SOLVER
- NLC.SOLVETIME
- NLC.SPECS
- NLC.TIME_SHIFT
- NLC.WEB
- NLC.WEB_MENU
- NLC.WEB_REFRESH
The database file contains options and model inputs for the current time instance.
The database file contains options and model inputs. The following is an exhaustive list of the configuration parameters for NLC type and FV, MV, SV, CV type. Each section includes an indication of the variable type (Integer or Real), the default value, data flow, and description.
APPINFO
DBS Parameters for Configuration
The configuration parameters before the model is parsed or data is input into the model structure. These parameters are read regardless of the value of NLC.DBS_READ. When NLC.DBS_READ = 0 (OFF) only the parameters associated with variables are skipped.
NLC.APPINFO
APPINFOCHG
NLC.APPINFOCHG
APPSTATUS
NLC.APPSTATUS
BNDS_CHK
NLC.BNDS_CHK
COLDSTART
NLC.COLDSTART
CSV_READ
NLC.CSV_READ
CSV_WRITE
NLC.CSV_WRITE
CTRLMODE
NLC.CTRLMODE
CTRL_HOR
NLC.CTRL_HOR
CTRL_TIME
NLC.CTRL_TIME
CTRL_UNITS
NLC.CTRL_UNITS
CV_TYPE
NLC.CV_TYPE
CV_WGT_SLOPE
NLC.CV_WGT_SLOPE
CV_WGT_START
NLC.CV_WGT_START
CYCLECOUNT
NLC.CYCLECOUNT
DBS_READ
NLC.DBS_READ
DBS_WRITE
NLC.DBS_WRITE
DIAGLEVEL
NLC.DIAGLEVEL
EV_TYPE
NLC.EV_TYPE
EV_WGT_SLOPE
NLC.EV_WGT_SLOPE
HIST_HOR
NLC.HIST_HOR
HIST_UNITS
NLC.HIST_UNITS
ICD_CALC
NLC.ICD_CALC
IMODE
NLC.IMODE
ITERATIONS
NLC.ITERATIONS
MAX_ITER
NLC.MAX_ITER
MAX_TIME
NLC.MAX_TIME
MEAS_CHK
NLC.MEAS_CHK
MV_DCOST_SLOPE
NLC.MV_DCOST_SLOPE
MV_STEP_HOR
NLC.MV_STEP_HOR
MV_TYPE
NLC.MV_TYPE
NODES
NLC.NODES
OBJFCNVAL
NLC.OBJFCNVAL
OTOL
NLC.OTOL
PRED_HOR
NLC.PRED_HOR
PRED_TIME
NLC.PRED_TIME
REQCTRLMODE
NLC.REQCTRLMODE
RTOL
NLC.RTOL
SOLVESTATUS
NLC.SOLVESTATUS
SOLVER
NLC.SOLVER
SOLVETIME
NLC.SOLVETIME
SPECS
NLC.SPECS
TIME_SHIFT
NLC.TIME_SHIFT
WEB
NLC.WEB
WEB_MENU
NLC.WEB_MENU
WEB_REFRESH
NLC.WEB_REFRESH
FV, MV, SV, and CV Parameters
The variable parameters are associated only with variables declared in the INFO file. They are not read when NLC.DBS_READ = 0 (OFF).
basic = 1
CASE ('DCOST
DCOST
basic = 1
basic = 1
basic = 1
basic = 1
basic = 1
basic = 1
basic = 1
basic = 1
MV_STEP_HOR
Type: Integer Default Value: 1 (for NLC.MV_STEP_HOR) or 0 (for MV(#).MV_STEP_HOR) Data Flow: Input Description: Step length for manipulated variables: 0 uses NLC.MV_STEP_HOR as default
basic = 1
basic = 1
basic = 1
basic = 1
basic = 1
basic = 1
basic = 1
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
DBS - Database File
The database file contains options and model inputs for the current time instance.
---
APPINFO
Type: Integer Default Value: 0 Data Flow: Input and Output Description: Application information: 0=good, error otherwise
---
APPINFOCHG
Type: Integer Default Value: 0 Data Flow: Output Description: Application information change (new-old): 0=no change
---
APPSTATUS
Type: Integer Default Value: 1 Data Flow: Output Description: Application status: 1=good, 0=bad
---
BNDS_CHK
Type: Integer Default Value: 1 Data Flow: Input Description: Bounds checking: 1=ON, 0=OFF
---
COLDSTART
Type: Integer Default Value: 0 Data Flow: Input and Output Description: Cold start model: 0=warm start, 1=cold start
---
CSV_READ
Type: Integer Default Value: 0 Data Flow: Input Description: CSV read: 0=Off, 1=Batch, 2=Sequential
---
CSV_WRITE
Type: Integer Default Value: 0 Data Flow: Input Description: CSV write: 0=Off, 1=On
---
CTRLMODE
Type: Integer Default Value: 1 Data Flow: Output Description: Control mode: 1=simulate, 2=predict, 3=control
---
CTRL_HOR
Type: Integer Default Value: 1 Data Flow: Input Description: Control horizon: Horizon length where MVs can be adjusted by the solver
---
CTRL_TIME
Type: Real Default Value: 60 Data Flow: Input Description: Time for each step in the control horizon
---
CTRL_UNITS
Type: Integer Default Value: 1 Data Flow: Input Description: Model time units (1=sec, 2=min, 3=hrs, 4=days, 5=yrs)
---
CV_TYPE
Type: Integer Default Value: 1 Data Flow: Input Description: Controlled variable error model type: 1=linear, 2=squared, 3=ref traj
---
CV_WGT_SLOPE
Type: Real Default Value: 0.0 Data Flow: Input Description: Slope for weight on future CV error (e.g. [+] favors steady state)
---
CV_WGT_START
Type: Integer Default Value: 0 Data Flow: Input Description: Start interval for controlled variable error model weights
---
CYCLECOUNT
Type: Integer Default Value: 0 Data Flow: Input and Output Description: Cycle count, increments every cycle
---
DBS_READ
Type: Integer Default Value: 1 Data Flow: Input Description: Database read: 1=ON, 0=OFF
---
DBS_WRITE
Type: Integer Default Value: 1 Data Flow: Input Description: Database write: 1=ON, 0=OFF
---
DIAGLEVEL
Type: Integer Default Value: 0 Data Flow: Input Description: Diagnostic level: 0=none, 1=messages, 2=file checkpoints, 4=diagnostic files, 5=check 1st deriv
---
EV_TYPE
Type: Integer Default Value: 1 Data Flow: Input Description: Estimated variable error model type: 1=linear, 2=squared, 3=approximate linear
---
EV_WGT_SLOPE
Type: Real Default Value: 0.0 Data Flow: Input Description: Slope for weight on more cuurent EV error (e.g. favor near-term matching)
---
HIST_HOR
Type: Integer Default Value: 0 Data Flow: Input Description: History horizon (SIM and CTL only): Integer >= 0
---
HIST_UNITS
Type: Integer Default Value: 0 Data Flow: Input Description: History time units on plots only (0=same as CTRL_UNITS, 1=sec, 2=min, 3=hrs, 4=days, 5=yrs)
---
ICD_CALC
Type: Integer Default Value: 0 Data Flow: Input Description: Specifications for initial condition differentials (MHE only): 0=OFF, 1=ON
---
IMODE
Type: Integer Default Value: 3 Data Flow: Input Description: Model solution mode: 1=ss, 2=mpu, 3=rto, 4=sim, 5=est, 6=ctl
---
ITERATIONS
Type: Integer Default Value: 1 Data Flow: Output Description: Iterations for solution: >=1
---
MAX_ITER
Type: Integer Default Value: 25 Data Flow: Input Description: Maximum iteration: >=1
---
MAX_TIME
Type: Real Default Value: 1.0e20 Data Flow: Input Description: Maximum run time in seconds
---
MEAS_CHK
Type: Integer Default Value: 1 Data Flow: Input Description: Measurement checking: 1=ON, 0=OFF
---
MV_DCOST_SLOPE
Type: Real Default Value: 0.1d0 Data Flow: Input Description: Slope for penalization on future MV moves (i.e. reduces controller procrastination)
---
MV_STEP_HOR
Type: Integer Default Value: 1 (for NLC.MV_STEP_HOR) or 0 (for MV(#).MV_STEP_HOR) Data Flow: Input Description: Step length for manipulated variables: 0 uses NLC.MV_STEP_HOR as default
---
MV_TYPE
Type: Integer Default Value: 0 Data Flow: Input Description: Manipulated variable type: 0=zero order hold, 1=linear
---
NODES
Type: Integer Default Value: 4 Data Flow: Input Description: Nodes in each horizon step
---
OBJFCNVAL
Type: Real Default Value: 0.0 Data Flow: Output Description: Objective function value
---
OTOL
Type: Real Default Value: 1.0e-6 Data Flow: Input Description: Objective function tolerance for successful solution
---
PRED_HOR
Type: Integer Default Value: 1.0 Data Flow: Input Description: Prediction horizon: Total horizon, including control horizon
---
PRED_TIME
Type: Real Default Value: 60.0 Data Flow: Input Description: Time for each step in the horizon
---
REQCTRLMODE
Type: Integer Default Value: 1 Data Flow: Input Description: Requested control mode: 1=simulate, 2=predict, 3=control
---
RTOL
Type: Real Default Value: 1.0e-6 Data Flow: Input Description: Equation solution tolerance
---
SOLVESTATUS
Type: Integer Default Value: 1 Data Flow: Output Description: Solution solve status: 1=good
---
SOLVER
Type: Integer Default Value: 3 Data Flow: Input Description: Solver options: 1=NOVA, 2=IPOPT-v2.3, 3=IPOPT-v3.5, 4=SNOPT, 5=MINOS
---
SOLVETIME
Type: Real Default Value: 1.0 Data Flow: Output Description: Solution time (seconds)
---
SPECS
Type: Integer Default Value: 1 Data Flow: Input Description: Secifications from restart file: 1=ON, 0=OFF
---
TIME_SHIFT
Type: Integer Default Value: 1 Data Flow: Input Description: Time shift for dynamic problems: 1=ON, 0=OFF
---
WEB
Type: Integer Default Value: 1 Data Flow: Input Description: Generate HTML pages: 1=ON, 0=OFF
---
WEB_MENU
Type: Integer Default Value: 1 Data Flow: Input Description: Generate HTML navigation menus: 1=ON, 0=OFF
---
WEB_REFRESH
Type: Integer Default Value: 10 Data Flow: Input Description: Automatic refresh rate on HTML pages (default 10 minutes)
---
COST
Type: Real Default Value: 0.0 Data Flow: Input Description: Cost weight: (+)=minimize, (-)=maximize basic = 1
---
CRITICAL
Type: Integer Default Value: 0 Data Flow: Input Description: Critical: 0=OFF, 1=ON' CASE ('DCOST Type: Real Default Value: 0.00001 Data Flow: Input Description: Delta cost penalty for MV movement basic = 1
---
DMAX
Type: Real Default Value: 1.0e20 Data Flow: Input Description: Delta MV maximum step per horizon interval basic = 1
---
DMAXHI
Type: Real Default Value: 1.0e20 Data Flow: Input Description: Delta MV positive maximum step per horizon interval basic = 1
---
DMAXLO
Type: Real Default Value: -1.0e20 Data Flow: Input Description: Delta MV negative maximum step per horizon interval basic = 1
---
DPRED
Type: Real Default Value: 0.0 Data Flow: Output Description: Delta prediction changes for each step'
---
FSTATUS
Type: Real Default Value: 1.0 Data Flow: Input Description: Feedback status: 1=ON, 0=OFF basic = 1
---
FDELAY
Type: Integer Default Value: 0 Data Flow: Input Description: Feedback delay: 0=No Delay, >=1 horizon steps for delay
---
LOWER
Type: Real Default Value: -1.0e20 Data Flow: Input Description: Lower bound basic = 1
---
LSTVAL
Type: Real Default Value: 1.0 Data Flow: Output Description: Last value from previous solution
---
MEAS
Type: Real Default Value: 1.0 Data Flow: Input Description: Measured value basic = 1
---
MEAS_GAP
Type: Real Default Value: 1.0 Data Flow: Input Description: Deadband for noise rejection of measurements in MHE
---
MODEL
Type: Real Default Value: 1.0 Data Flow: Output Description: Model predicted value basic = 1
---
NEWVAL
Type: Real Default Value: 1.0 Data Flow: Output Description: New value implemented by the estimator or controller (NEWVAL = MEAS when not in control) basic = 1
---
NXTVAL
Type: Real Default Value: 1.0 Data Flow: Output Description: Next value that the estimator or controller would implement were it on
---
OBJPCT
Type: Real Default Value: 0.0 Data Flow: Output Description: Percent of objective function contibution considering all SV and CV variables
---
OSTATUS
Type: Integer Default Value: 0 Data Flow: Input and Output Description: Bit encoding for status messages
---
OSTATUSCHG
Type: Integer Default Value: 0 Data Flow: Input Description: Change in bit encoding for status messages
---
PRED
Type: Real Default Value: 1.0 Data Flow: Output Description: Prediction horizon
---
PSTATUS
Type: Integer Default Value: 1 Data Flow: Input Description: Instrument status: 1=GOOD, 0=BAD
---
REQONCTRL
Type: Integer Default Value: 0 Data Flow: Input Description: Required for control mode to be ON (3): 1=ON, 0=OFF
---
SP
Type: Real Default Value: 0.0 Data Flow: Input Description: Set point for squared error model basic = 1
---
SPHI
Type: Real Default Value: 1.0e20 Data Flow: Input Description: Set point high for linear error model basic = 1
---
SPLO
Type: Real Default Value: -1.0e20 Data Flow: Input Description: Set point low for linear error model basic = 1
---
STATUS
Type: Integer Default Value: 0 Data Flow: Input Description: Status: 1=ON, 0=OFF basic = 1
---
TAU
Type: Real Default Value: 60.0 Data Flow: Input Description: Time constant for controlled variable response basic = 1
---
TR_OPEN
Type: Real Default Value: 1.0 Data Flow: Input Description: Initial trajectory opening ratio (0=ref traj, 1=tunnel, 2=funnel)
---
TR_INIT
Type: Integer Type: Real Default Value: 1 Data Flow: Input Description: Traj initialization (0=dead-band, 1=re-center with coldstart/out-of-service, 2=re-center always)
---
UPPER
Type: Real Default Value: 1.0e20 Data Flow: Input Description: Upper bound basic = 1
---
VDVL
Type: Real Default Value: 1.0e20 Data Flow: Input Description: Delta validity limit
---
VLHI
Type: Real Default Value: 1.0e20 Data Flow: Input Description: Upper validity limit
---
VLLO
Type: Real Default Value: -1.0e20 Data Flow: Input Description: Lower validity limit
---
WMEAS
Type: Real Default Value: 20.0 Data Flow: Input Description: Objective function weight on measured value
---
WMODEL
Type: Real Default Value: 2.0d0 Data Flow: Input Description: Objective function weight on model value
---
WSP
Type: Real Default Value: 1.0 Data Flow: Input Description: Objective function weight on set point for squared error model
---
WSPHI
Type: Real Default Value: 1.0 Data Flow: Input Description: Objective function weight on upper set point for linear error model
---
WSPLO