
Variable subjects, sparse samples and limits that cannot be crossed
Living systems differ from one individual to the next and are sampled rarely. Thirteen systems, from cell culture and digesters to insulin delivery and pacing an athlete, show control under variability and hard physiological limits.
pages 1–22
Artificial Pancreas Control Studio · pages 23–53
An insulin pump can only lower glucose, it stops at zero, and a low glucose costs more than a high one of the same size. How should a direct-acting PI loop be tuned when its actuator pushes one way and its error is not symmetric, and what does a predictive controller gain when it is told of a meal?
Closed-Loop Anesthesia Depth Control · pages 54–85
An infusion pump holds the drug concentration its population model predicts, which is exact on the patient the model was built from and silently wrong on anybody else. What does an outer loop on a depth monitor add to that model inversion, and which structural choices matter more than its tuning?
Mechanical Ventilator · pages 86–110
A ventilator measures pressure and flow at the wye, while the leak, the patient's effort and the lung stay hidden. What does each mode hold, and when do the breath the machine reports and the breath the lung receives part company?
Continuous Kidney Replacement Fluid Control · pages 111–136
The water a patient on continuous kidney replacement should lose is the small difference of liters an hour pumped in and out. What does a balance loop on a weighed running total remove, what does it pass to the patient while its own error stays small, and which second measurement shows the difference?
Treadmill Pacing for One-Hour Distance · pages 137–168
Belt speed is the only actuator of a treadmill, while blood lactate, heart rate, core temperature and fuel limit how fast it may run and answer on different time scales. How should one actuator be shared among those limits, and what is a finite store worth when the hour has a fixed end?
Cycling Exertion and Pacing · pages 169–201
A rider sets exertion, and the watts that exertion buys fall as a finite work capacity drains. How should a pacing loop and two slow physiological limits share that one actuator, and what is the terrain or the end of the ride worth to a controller that plans ahead?
Monoclonal Antibody Fed-Batch Bioreactor · pages 202–233
An antibody culture's appetite for glucose doubles with its cells, halves when the broth is cooled, and is measured directly only in a sample drawn once a day and reported four hours later. Which feed holds the glucose low but never at zero, and what does each correction of oxygen, pH and glucose leave behind in the broth?
Insulin Recovery and Refolding · pages 234–255
Unfolded insulin precursor either folds, at a rate first order in its concentration, or aggregates, at a rate second order in it, so a lot charged slowly keeps more protein than a lot charged at once. The refolding vessel is also the bottleneck of the recovery train, so the question is when a charge that folds more protein pays for the vessel hours it costs.
Brewery Fermentation Tank · pages 256–279
A lager tank has only open-or-shut glycol valves, is mixed only while its yeast release gas, ends its diacetyl rest on a result a day old and shares its glycol plant with the cellar. Does the tuning of its temperature loops decide the batch, or do the phase triggers, the endpoint, the probe placement and the shared utility?
Anaerobic Digester and Renewable Natural Gas · pages 280–303
More feed raises a digester's biogas for a day before the acids consume its buffer and the tank sours for weeks. How close to that fold can a feed loop run when the only timely warning of the acids is a titration drawn once a day and reported six hours later?
Recirculating Aquaculture System · pages 304–325
A recirculating farm removes its fish's ammonia with a biofilter of two nitrifier populations that grow only on the load they carry, so a larger ration returns as nitrite days after the feed changes. How can a farm that measures its water every four hours and weighs its fish every two weeks feed for growth without poisoning the fish?
Greenhouse Climate Control · pages 326–350
A tomato crop answers the mean temperature of its day, so a glasshouse can spend its heat where it is cheapest, while the humidity under a closed screen must hold hour by hour. How much does a planner over the weather forecast save against fixed setpoints, and what does the humidity limit cost once one air exchange carries heat, water and carbon dioxide together?
Epidemic Response Control · pages 351–372
A city counts its cases a week after the onsets they sample, finds only a share of them, and fills its hospital beds two weeks after the infections. What can an estimator recover from those counts, and which policy keeps the census under the beds when testing changes and a variant arrives unannounced?
pages 373–387