Cover of Volume 17: a wind turbine, solar troughs, storage tanks and a pylon
Industry applications · Volume 17

Control of Energy Conversion and Storage

Fast regulation and slow dispatch on a changing grid

Generation, storage and demand must balance every second and pay for themselves every day. Twelve systems connect the fast loops that hold frequency and voltage to the slow decisions that dispatch stored energy.

Series
Interactive Control Engineering: Principles and Applications, Volume 17 of 20
Editor
John D. Hedengren
Publisher
Advanced Process Solutions, LLC, 2026
Pages
392

Contents

  1. 1

    Introduction: From Inertia to Dispatch

    pages 1–22

  2. 2

    Gas Engine Cogeneration Where Power Settles in Seconds and Heat in Minutes

    Reciprocating Gas Engine CHP · pages 23–48

    One fuel valve per engine sets both the electricity and the recovered heat, but the power settles in seconds and the heat in minutes. Which control layer of a three-engine plant at a data center holds which balance, and when does a shortfall stop being a tuning problem and become a lack of capacity?

  3. 3

    Solid Oxide Fuel Cell Current That Waits for Its Fuel

    Solid Oxide Fuel Cell CHP · pages 49–79

    A solid oxide fuel cell can change its current within a fraction of a second, but the hydrogen that current consumes reaches the anode only after tens of seconds in a fuel processor. How does a controller make the current wait for its fuel, and what carries the load while it waits?

  4. 4

    Torque-to-Pitch Handover and Gain Scheduling in a Wind Turbine Simulator

    Wind Turbine Control · pages 80–110

    A large wind turbine regulates one rotor speed with two actuators, generator torque below rated wind and collective pitch above it, and the pitch sensitivity of its rotor grows by a factor of 4.9 across the range above rated. How should the two actuators hand over, and what do a gain schedule and a predictive controller told the wind ahead buy and cost?

  5. 5

    Energy-Maximizing Control of a Heaving Buoy on a Fading Wave Forecast

    Wave Energy Converter Control · pages 111–133

    The force that takes the most energy from a wave depends on waves still to come. How much of that anticausal optimum can a controller reach on a forecast built from its own motion, inside a stroke and a force rating that bind in the most energetic seas?

  6. 6

    A Parabolic-Trough Simulator for Choosing a Setpoint Rather Than Defending One

    Parabolic-Trough Solar Thermal Storage · pages 134–162

    A trough receiver loses heat as the fourth power of its temperature whether or not the sun is out, while the power block converts hotter oil more efficiently. When is the outlet temperature setpoint itself the decision worth automating, and when is the schedule of the power block worth more than either the setpoint or the tuning?

  7. 7

    Forming the Grid From a Battery When a Campus Microgrid Islands

    Islanded Microgrid · pages 163–190

    When the utility's breaker opens, one of the island's own sources has to make the voltage that the others follow. What does each layer above that source, from virtual inertia and droop to load shedding, charge management and the sync check, buy a campus in hertz, megawatts and critical load kept on?

  8. 8

    Hunting, Reverse Flow and an Unmeasured Customer on a Solar Distribution Feeder

    Distribution Feeder Voltage Regulation with Rooftop Solar · pages 191–217

    A substation tap changer moves the whole feeder in steps after a timer, while rooftop solar reverses the flow at noon, clouds move the far end in seconds and inverters answer at every node. Which device should set the level and which should trim the spread, and what does a central controller that reads only the utility's measurements add?

  9. 9

    Electric Vehicle Fast Charge Simulator for Selector Control of an Unmeasured Constraint

    EV Fast Charge and Pack Thermal Management · pages 218–247

    Four limits share one charging current, and the one that ends a fast charge, the anode surface potential, has no instrument. How should a selector defend a constraint it can only compute, and what margin does an error in that computation cost?

  10. 10

    A Vanadium Flow Battery Simulator for Inventory-Constrained Dispatch on a Duck Curve

    Vanadium Flow Battery and the Duck Curve · pages 248–274

    A flow battery buys its megawatts as stacks and its megawatt-hours as electrolyte, and a converter answers a power command in seconds. When should a finite inventory be spent on a duck-curve feeder, and when is a forecast worth more than feedback on the net load?

  11. 11

    A Salt-Cavern Air Storage Simulator for Inventory Policy Under a Capacity Commitment

    Seasonal Salt-Cavern Compressed-Air Storage · pages 275–299

    A compressed-air plant stores mass in a salt cavern but sells a capacity commitment in megawatts. Which inventory, the gas or the heat, decides whether a winter commitment is kept, and what must a reserve count to protect it?

  12. 12

    A Solar Hydrogen Simulator for Safety Interlocks and the Question of Keeping the Oxygen

    Solar Electrolysis with Hydrogen and Oxygen Storage · pages 300–322

    A solar hydrogen plant returns about a third of the electricity it takes in, and no controller changes that. What does control decide on such a plant, why must interlocks choose the mode while economics only choose setpoints inside it, and is the oxygen worth keeping?

  13. 13

    Supervisory Economic Dispatch of Nuclear Heat, Storage and Hydrogen Production

    Nuclear Heat, Storage and Hydrogen Dispatch · pages 323–351

    A reactor that cannot be turned down sells into a market whose price moves sixteen to one across a day. How much does a supervisory economic optimizer earn over three price thresholds an engineer can defend, and on which days does its horizon pay for itself?

  14. 14

    Summary and Outlook

    pages 352–366

Cite