Recycle, equilibrium and energy in continuous chemical processes
In a synthesis loop most of what enters the reactor has been there before. Ten plants, from ammonia and urea to air separation and carbon capture, show how recycle, equilibrium and energy cost shape the control structure.
pages 1–23
Ammonia Synthesis Loop · pages 24–52
An ammonia converter reacts about four percent of the gas on each pass, so the plant is a recycle with a converter inside it. How far and how slowly does the loop amplify a small error in the makeup gas, and which variable should the makeup valve hold: the loop pressure or the production rate?
Urea Synthesis Loop · pages 53–75
The molar ratio of ammonia to carbon dioxide in a urea reactor sets the conversion, the pressure the liquid needs and whether the stainless liner stays passive, and no online instrument measures it. Can a ratio held on the two feed flows hold it, and what do an inference from the reactor's density and temperature, corrected by a laboratory that reports 45 min late, and a predictive controller add?
Sulfuric Acid Contact Plant · pages 76–98
Each adiabatic bed of a contact plant climbs a straight line until it meets the equilibrium curve, so the coolest inlet that still lights the catalyst converts the most. How close to that ignition floor can inlet loops, an air ratio, an analyzer trim and a predictive layer hold four beds through a turndown, a richer sulfur and an aged catalyst?
Chlor-Alkali Membrane Electrolysis · pages 99–123
A membrane electrolyzer makes every product in proportion to one current, and its hydrogen must stay a few tens of millibars above its chlorine. What do feeds in ratio to the current, a chlorine pressure feedforward on the hydrogen header and a load plan on the electricity price each buy, and which losses can no controller recover?
Cryogenic Air Separation Unit · pages 124–155
One shell is the condenser of one column and the reboiler of the other, so all reflux and boil-up come from one duty. Which handle should each purity loop own when the strongest one belongs to the argon loop, and how are failures that hold every setpoint seen?
Post-Combustion CO₂ Capture · pages 156–186
A capture plant's solvent takes seventy minutes to come back round its circuit, so every move of the circulation acts through a recycle. What sets the gain of the capture loop, and when should the regeneration energy, bought out of the host station's saleable output, be spent?
Dividing-Wall Column · pages 187–209
Three purity loops use three of a dividing-wall column's four handles, and the fourth, the liquid split above the wall, moves only the reboiler duty along a valley whose minimum shifts with the feed. How is the column kept in that valley when the feed changes, and what does each control structure cost on the way?
MTBE Reactive Distillation · pages 210–232
At one set of feeds and one reboiler duty, an MTBE column can convert most of its isobutene, lose its methanol into the stripping trays, or fail to strip its C4. Which steady state does the column reach, and what does a stripping-tray temperature loop tuned on one of them do on the others?
Synthetic Base Oil Plant · pages 233–254
A reactor and a column cut point can both put a base oil on its viscosity, one in about an hour and one in a quarter of an hour, and the two routes make different oils. How should the two handles be arranged, how is a drifting meter corrected from a late laboratory, and how far should the plant stay from a viscosity index limit that only the laboratory can see?
Williams–Otto Plant and Real-Time Optimization · pages 255–281
A real-time optimizer moves the setpoints of a reactor's loops to the best steady state its model can find, and its model lacks one of the plant's three reactions. Refitted at every steady state, the model agrees with the plant where it stands but not on the slopes. Where does such an optimizer stop, and what does it cost to correct the slopes from plant data?
pages 282–295