Choosing a structure from where the disturbance enters
A single loop can only react after the upset arrives. Eleven plants show when to measure the disturbance and act first, when to nest a fast loop inside a slow one, and when to hold a ratio.
pages 1–21
Feedforward Cascade Control Studio · pages 22–45
A tank held on level by an inlet valve meets two upsets that enter at different points, a supply pressure swing at the valve and a step in the outlet demand. Which control structure rejects which upset, and what does a structure chosen for the wrong one cost?
Ethanol Bioreactor Dissolved-Oxygen Cascade · pages 46–74
The agitator drive, the dissolved oxygen in the broth and the membrane probe of a fermenter respond within a factor of two of one another. How fast must the speed loop of an oxygen cascade be before it helps rather than hurts, and which of the three lags can any control structure reach?
Fired Heater Combustion and Excess-Oxygen Trim · pages 75–93
The forced-draft fan of a fired heater answers six times more slowly than its fuel valve, and too little air is a hazard while too much is a cost. How does a pair of selectors keep the burners lean through a load step, and why does a carbon monoxide override, not an oxygen setpoint, find the best legal operating point?
Organic Rankine Cycle Waste Heat Recovery · pages 94–124
When the waste heat behind an organic Rankine cycle falls by a third within seconds, can a well-tuned superheat loop keep the expander inlet dry, and which limits of the condenser and the heat source does no control structure remove?
Municipal Water Treatment Plant · pages 125–144
The settled-water turbidimeter that judges the coagulant dose reads three hours after the dosing pump, and a storm raises the raw turbidity fivefold in half an hour. Where should the dose be computed, and what is left for the slow measurement, the pH loop and the filter sequence to do?
Beverage Blending and Carbonation · pages 145–170
The CO₂ analyzer measures a content, but the filler needs a margin between the tank's top pressure and the product's own gas pressure. How can a line whose analyzer reads its setpoint fill foaming product, and which of cooling, top pressure and throughput buys the margin back?
mRNA Lipid-Nanoparticle Formulation · pages 171–195
The particles of this skid grow for as long as the mixed stream ages before a quench arrests them, so a loop volume and a total flow act on one quality attribute. What does timing the quench buy that ratio control on four feeds cannot, and what can a blend of channels behind one set of meters hide?
DC-DC Boost Converter · pages 196–224
Raising the duty of a boost converter starves the output before it feeds it, and that right-half-plane zero belongs to the power stage. What does it cost a voltage loop, and what does an inner current loop buy that more gain cannot?
2-D Rocket Landing · pages 225–254
A lander on one gimballed engine cannot push itself sideways, so its position loop commands a tilt and borrows its authority from an attitude loop. How fast may that outer loop be, when the engine hung below the center of mass puts a right-half-plane zero in its path that no attitude gain can move?
Orbital Rendezvous and Station Keeping · pages 255–285
A chaser near a target in orbit is flown in axes that turn once per orbit, and the gravity-gradient and Coriolis terms make three thrusters on three axes a coupled plant. What does canceling that known coupling by feedforward buy that more feedback gain cannot, and what does it cost in propellant?
Space Elevator Transport Rail · pages 286–312
A climber on a space elevator ribbon carries a weight that falls from 9.76 at the anchor to zero at the geostationary radius, and every change of its speed pushes the ribbon sideways through the Coriolis force. What do a gravity feedforward, a speed schedule, an input shaper and a feasibility supervisor each contribute when the load, the structure and the limits all change along the route?
pages 313–325