FSTATUS - APMonitor Option
Main.OptionFstatus History
Show minor edits - Show changes to output
Changed line 21 from:
See also [[https://apmonitor.com/do/index.php/Main/EstimatorObjective|Estimation Objective Tuning]], [[Main/OptionFstatus|FSTATUS]], [[Main/OptionMeas|MEAS]]
to:
See also [[https://apmonitor.com/do/index.php/Main/EstimatorObjective|Estimation Objective Tuning]], [[Main/OptionFstatus|FSTATUS]], [[Main/OptionLstval|LSTVAL]], [[Main/OptionMeas|MEAS]]
Changed line 21 from:
See also [[https://apmonitor.com/do/index.php/Main/EstimatorObjective|Estimation Objective Tuning]]
to:
See also [[https://apmonitor.com/do/index.php/Main/EstimatorObjective|Estimation Objective Tuning]], [[Main/OptionFstatus|FSTATUS]], [[Main/OptionMeas|MEAS]]
Changed line 5 from:
%width=50px%Attach:fv.png %width=50px%Attach:mv.png %width=50px%Attach:sv.png %width=50px%Attach:cv.png
to:
%width=50px%Attach:fv.png %width=50px%Attach:mv.png %width=50px%Attach:sv.png %width=50px%Attach:cv.png [[Main/DbsVariable|Local Options]] | %width=30px%Attach:apm.png [[Main/DbsGlobal|Global Options]]
Changed lines 19-21 from:
The actual process value steps from 0.85 to 1.0 and the measurement is the true value with random white noise. The Filtered trends show the value of MEAS used in the model simulation with varying levels of FSTATUS.
to:
The actual process value steps from 0.85 to 1.0 and the measurement is the true value with random white noise. The Filtered trends show the value of MEAS used in the model simulation with varying levels of FSTATUS. Lower values of FSTATUS (such as 0.1) require more cycles to update to true measured values but are also less sensitive to noise (random fluctuations). A higher value of FSTATUS (such as 0.7) incorporates more of the measurement information but does not filter out the random fluctuations as well. FSTATUS should be chosen as a balance between these trade-offs.
Changed line 17 from:
%width=500px%Attach:filtered_input.png
to:
%width=400px%Attach:filtered_input.png
Changed lines 11-21 from:
Determines how much of the measurement (MEAS) to use in updating the values in the model. A feedback status of 0 indicates that the measurement should not be used either in estimation or in updating a parameter in the model. A feedback status of 1 uses all of the measurement. A feedback status in between updates the model OR parameter value (x) according to the formula: x = LSTVAL * (1-FSTATUS) + MEAS * FSTATUS.
to:
Determines how much of the measurement (MEAS) to use in updating the values in the model. A feedback status of 0 indicates that the measurement should not be used either in estimation or in updating a parameter in the model. A feedback status of 1 uses all of the measurement. A feedback status in between 0 and 1 updates MEAS with a fractional contribution from LSTVAL and the new measurement.
MEAS = LSTVAL * (1-FSTATUS) + MEAS * FSTATUS
It may be desirable to set FSTATUS between 0.0 and 1.0 to filter out noise from measurements while maintaining a sufficiently fast response time to actual shifts. Below is an example with FSTATUS at 0.1, 0.3, and 0.7.
%width=500px%Attach:filtered_input.png
The actual process value steps from 0.85 to 1.0 and the measurement is the true value with random white noise. The Filtered trends show the value of MEAS used in the model simulation with varying levels of FSTATUS.
MEAS = LSTVAL * (1-FSTATUS) + MEAS * FSTATUS
It may be desirable to set FSTATUS between 0.0 and 1.0 to filter out noise from measurements while maintaining a sufficiently fast response time to actual shifts. Below is an example with FSTATUS at 0.1, 0.3, and 0.7.
%width=500px%Attach:filtered_input.png
The actual process value steps from 0.85 to 1.0 and the measurement is the true value with random white noise. The Filtered trends show the value of MEAS used in the model simulation with varying levels of FSTATUS.
Added lines 12-13:
See also [[https://apmonitor.com/do/index.php/Main/EstimatorObjective|Estimation Objective Tuning]]
Added lines 1-11:
(:title FSTATUS - APMonitor Option:)
(:keywords FSTATUS, Optimization, Estimation, Option, Configure, Default, Description:)
(:description Feedback status: 1=ON, 0=OFF:)
%width=50px%Attach:fv.png %width=50px%Attach:mv.png %width=50px%Attach:sv.png %width=50px%Attach:cv.png
Type: Floating Point, Input
Default Value: 1.0
Description: Feedback status: 1=ON, 0=OFF
Determines how much of the measurement (MEAS) to use in updating the values in the model. A feedback status of 0 indicates that the measurement should not be used either in estimation or in updating a parameter in the model. A feedback status of 1 uses all of the measurement. A feedback status in between updates the model OR parameter value (x) according to the formula: x = LSTVAL * (1-FSTATUS) + MEAS * FSTATUS.
(:keywords FSTATUS, Optimization, Estimation, Option, Configure, Default, Description:)
(:description Feedback status: 1=ON, 0=OFF:)
%width=50px%Attach:fv.png %width=50px%Attach:mv.png %width=50px%Attach:sv.png %width=50px%Attach:cv.png
Type: Floating Point, Input
Default Value: 1.0
Description: Feedback status: 1=ON, 0=OFF
Determines how much of the measurement (MEAS) to use in updating the values in the model. A feedback status of 0 indicates that the measurement should not be used either in estimation or in updating a parameter in the model. A feedback status of 1 uses all of the measurement. A feedback status in between updates the model OR parameter value (x) according to the formula: x = LSTVAL * (1-FSTATUS) + MEAS * FSTATUS.