Level Regulation with MPC

Main.LevelControl History

Show minor edits - Show changes to output

March 27, 2018, at 03:49 PM by 45.56.3.173 -
Changed lines 5-7 from:
Develop a model predictive controller (MPC) to reach a level set point for tank 2 (e.g. 50% full, level=0.5), initially starting from empty tanks. Tune the controller for satisfactory performance with setpoint changes in the level or with disturbances to the valve position ({`\gamma_1`}). Demonstrate the control performance and discuss methods used to achieve satisfactory control during startup from empty and with valve position changes (show both of these).
to:
[[https://en.wikipedia.org/wiki/Pumped-storage_hydroelectricity|Pumped-storage hydroelectricity]] is a promising method to improve energy dispatch potential with increasing renewable sources such as wind and solar. The following application is a dual reservoir system with pumped water that either enters the upper or lower reservoir.

You are asked to develop
a model predictive controller (MPC) to reach a level set point for tank 2 (e.g. 50% full, level=0.5), initially starting from empty tanks. Tune the controller for satisfactory performance with setpoint changes in the level or with disturbances to the valve position ({`\gamma_1`}). Demonstrate the control performance and discuss methods used to achieve satisfactory control during startup from empty and with valve position changes (show both of these).
March 27, 2018, at 03:41 PM by 45.56.3.173 -
Added lines 12-15:

(:html:)
<iframe width="560" height="315" src="https://www.youtube.com/embed/YvU3Rd3JBc0" frameborder="0" allow="autoplay; encrypted-media" allowfullscreen></iframe>
(:htmlend:)
March 27, 2018, at 02:46 PM by 45.56.3.173 -
Changed line 18 from:
where ''1'' and ''2'' refer to the tanks, {`\tau_1`} and {`\tau_2`} are time constants, {`K_1`} and {`K_2`} are gains, {`h_1`} and {`h_2`} are liquid level heights, and ''p'' is the pump flow between ''0'' and ''1''.
to:
where ''1'' and ''2'' refer to the tanks, {`\tau_1=18.4`} and {`\tau_2=24.4`} are time constants, {`K_1=1.3`} and {`K_2=1.0`} are gains, {`h_1`} and {`h_2`} are liquid level heights, and ''p'' is the pump flow between ''0'' and ''1''.
March 27, 2018, at 05:39 AM by 45.56.3.173 -
Changed lines 48-49 from:
h1 = m.SV(value=0)
to:
h1 = m.Var(value=0.0)
Changed line 51 from:
h2 = m.CV(value=0)
to:
h2 = m.CV(value=0.0)
Changed lines 55-56 from:
to:
h2.TR_INIT = 1
Changed lines 63-64 from:
m.options.CV_TYPE = 1
to:
m.options.CV_TYPE = 2
Deleted line 115:
   print('h2: ' + str(h2.MEAS))
Added line 119:
   h2.SP = sp[i]
Changed lines 124-125 from:
   print('pump: ' + str(pump[i]))
   
to:
Changed line 136 from:
  
to:
Changed line 138 from:
   if (i%5==1):
to:
   if (i%5==3):
March 23, 2018, at 06:41 PM by 10.37.71.107 -
Added lines 164-165:
Attach:download.png [[Attach:final_solution3_steps_python.zip|Dual Tank: Step Test for Model Identification (Python/Excel)]]
Deleted lines 172-176:
Attach:download.png [[Attach:final_solution3_steps_python.zip|Dual Tank: Step Test for Model Identification (Python/Excel)]]

(:html:)
<iframe width="560" height="315" src="https://www.youtube.com/embed/U7uyj9BaNKg" frameborder="0" allowfullscreen></iframe>
(:htmlend:)
March 23, 2018, at 03:52 PM by 10.5.113.167 -
Added lines 10-11:

Attach:download.png [[Attach:level_simulation.zip|Dual Tank Simulation Files (Simulink and Python)]]
March 23, 2018, at 03:50 PM by 10.5.113.167 -
Deleted lines 19-20:
%width=550px%Attach:gravity_tank_mpc.png
Added lines 157-158:

%width=550px%Attach:gravity_tank_mpc.png
March 23, 2018, at 03:49 PM by 10.5.113.167 -
Changed line 20 from:
Attach:gravity_tank_mpc.png
to:
%width=550px%Attach:gravity_tank_mpc.png
March 23, 2018, at 03:44 PM by 10.5.113.167 -
Changed line 164 from:
Attach:2tank_linear_MPC.png
to:
%width=400px%Attach:2tank_linear_MPC.png
March 23, 2018, at 03:43 PM by 10.5.113.167 -
Added lines 159-176:

!!!! Python (APM) Solution

Attach:download.png [[Attach:final_solution3_python_mpc.zip|Dual Tank: Linear MPC Solution (Python)]]

Attach:2tank_linear_MPC.png

!!!! Simulink Solution

Attach:download.png [[Attach:final_solution3_steps_simulink.zip|Dual Tank: Step Test for Model Identification (Simulink/Excel)]]
Attach:download.png [[Attach:final_solution3_steps_python.zip|Dual Tank: Step Test for Model Identification (Python/Excel)]]

(:html:)
<iframe width="560" height="315" src="https://www.youtube.com/embed/U7uyj9BaNKg" frameborder="0" allowfullscreen></iframe>
(:htmlend:)

Attach:download.png [[Attach:final_solution3_linear_mpc.zip|Dual Tank: Linear MPC Solution (MATLAB/Simulink)]]

March 23, 2018, at 03:40 PM by 10.5.113.167 -
Changed line 7 from:
%width=300px%Attach:2tank_level.png
to:
%width=200px%Attach:2tank_level.png
March 23, 2018, at 03:40 PM by 10.5.113.167 -
Added lines 7-8:
%width=300px%Attach:2tank_level.png
Changed lines 13-14 from:
{$\tau_{1} * \frac{h_1}{dt} = -h_1 + K_1 \, p$}
{$\tau_{2} * \frac{h_2}{dt} = -h_2 + K_2 \, h_1$}
to:
{$\tau_{1} \frac{h_1}{dt} = -h_1 + K_1 \, p$}
{$\tau_{2} \frac{h_2}{dt} = -h_2 + K_2 \, h_1$}
March 23, 2018, at 03:38 PM by 10.5.113.167 -
Added lines 1-156:
(:title Level Regulation with MPC:)
(:keywords Python, MATLAB, linear control, model predictive control, level, height, liquid, dynamic programming:)
(:description Design a model predictive controller for level control in a dual tank system. Show that the controller is able to maintain a set point that changes at frequent intervals.:)

Develop a model predictive controller (MPC) to reach a level set point for tank 2 (e.g. 50% full, level=0.5), initially starting from empty tanks. Tune the controller for satisfactory performance with setpoint changes in the level or with disturbances to the valve position ({`\gamma_1`}). Demonstrate the control performance and discuss methods used to achieve satisfactory control during startup from empty and with valve position changes (show both of these).

A pump transports water to tank 1 where it drains to tank 2. Both tanks have an opening at the bottom that allows liquid to flow out. A valve is used to divert pumped liquid into tank 1 (valve position=0), into tank 2 (valve position=1) or fractionally into both (valve position 0-1). The valve position is not available to the controller as a measurement and is considered a disturbance to the process. Only the level of tank 2 (bottom tank) is available as a measured value. The pump rate can be manipulated between 0 and 1. The pump has a maximum rate of change of 0.1 every second.

For control you can use linear or nonlinear model predictive control. For estimation, you can use moving horizon estimation (MHE) or simple bias updating. The simplest option is linear MPC with bias updating. The following is a linear second order model that approximates the level dynamics.

{$\tau_{1} * \frac{h_1}{dt} = -h_1 + K_1 \, p$}
{$\tau_{2} * \frac{h_2}{dt} = -h_2 + K_2 \, h_1$}

where ''1'' and ''2'' refer to the tanks, {`\tau_1`} and {`\tau_2`} are time constants, {`K_1`} and {`K_2`} are gains, {`h_1`} and {`h_2`} are liquid level heights, and ''p'' is the pump flow between ''0'' and ''1''.

!!!! Python (GEKKO Solution)

Attach:gravity_tank_mpc.png

(:toggle hide gekko button show="Show GEKKO (Python) Code":)
(:div id=gekko:)
(:source lang=python:)
import numpy as np
import matplotlib.pyplot as plt
from scipy.integrate import odeint
import csv
from gekko import GEKKO

# create MPC with GEKKO
m = GEKKO()
m.time = [0,1,2,4,8,12,16,20]

# empirical constants
Kp_h1 = 1.3
tau_h1 = 18.4
Kp_h2 = 1
tau_h2 = 24.4

# manipulated variable
p = m.MV(value=0,lb=1e-5,ub=1)
p.STATUS = 1
p.DCOST = 0.01
p.FSTATUS = 0

# unmeasured state
h1 = m.SV(value=0)

# controlled variable
h2 = m.CV(value=0)
h2.STATUS = 1
h2.FSTATUS = 1
h2.TAU = 20

# equations
m.Equation(tau_h1*h1.dt()==-h1 + Kp_h1*p)
m.Equation(tau_h2*h2.dt()==-h2 + Kp_h2*h1)

# options
m.options.IMODE = 6
m.options.CV_TYPE = 1

# simulated system (for measurements)
def tank(levels,t,pump,valve):
    h1 = max(1.0e-10,levels[0])
    h2 = max(1.0e-10,levels[1])
    c1 = 0.08 # inlet valve coefficient
    c2 = 0.04 # tank outlet coefficient
    dhdt1 = c1 * (1.0-valve) * pump - c2 * np.sqrt(h1)
    dhdt2 = c1 * valve * pump + c2 * np.sqrt(h1) - c2 * np.sqrt(h2)
    if h1>=1.0 and dhdt1>0.0:
        dhdt1 = 0
    if h2>=1.0 and dhdt2>0.0:
        dhdt2 = 0
    dhdt = [dhdt1,dhdt2]
    return dhdt

# Initial conditions (levels)
h0 = [0,0]

# Time points to report the solution
tf = 400
t = np.linspace(0,tf,tf+1)

# Set point
sp = np.zeros(tf+1)
sp[5:100] = 0.5
sp[100:200] = 0.8
sp[200:300] = 0.2
sp[300:] = 0.5

# Inputs that can be adjusted
pump = np.zeros(tf+1)

# Disturbance
valve = 0.0

# Record the solution
y = np.zeros((tf+1,2))
y[0,:] = h0

# Create plot
plt.figure(figsize=(10,7))
plt.ion()
plt.show()

# Simulate the tank step test
for i in range(1,tf):
    #########################
    # MPC ###################
    #########################
    # measured height
    h2.MEAS = y[i,1]
    print('h2: ' + str(h2.MEAS))
    # set point deadband
    h2.SPHI = sp[i]+0.01
    h2.SPLO = sp[i]-0.01
    # solve MPC
    m.solve(disp=False)
    # retrieve 1st pump new value
    pump[i] = p.NEWVAL
    print('pump: ' + str(pump[i]))
   
    #########################
    # System ################
    #########################
    # Specify the pump and valve
    inputs = (pump[i],valve)
    # Integrate the model
    h = odeint(tank,h0,[0,1],inputs)
    # Record the result
    y[i+1,:] = h[-1,:]
    # Reset the initial condition
    h0 = h[-1,:]
   
    # update plot every 5 cycles
    if (i%5==1):
        plt.clf()
        plt.subplot(2,1,1)
        plt.plot(t[0:i],sp[0:i],'k-')   
        plt.plot(t[0:i],y[0:i,0],'b-')
        plt.plot(t[0:i],y[0:i,1],'r--')
        plt.ylabel('Height (m)')
        plt.legend(['Set point','Height 1','Height 2'])
        plt.subplot(2,1,2)
        plt.plot(t[0:i],pump[0:i],'k-')
        plt.ylabel('Pump')   
        plt.xlabel('Time (sec)')
        plt.draw()
        plt.pause(0.01)

# Construct and save data file
data = np.vstack((t,pump))
data = np.hstack((np.transpose(data),y))
np.savetxt('data.txt',data,delimiter=',')
(:sourceend:)
(:divend:)