Cover of Volume 14: a wafer in a process chamber with run-to-run corrections converging on target
Industry applications · Volume 14

Control in Semiconductor Manufacturing

Run-to-run control where little can be measured in the chamber

A wafer is processed in seconds and measured an hour later. Ten tools, from crystal growth through lithography, etch, implant and polish, show how each run corrects the next.

Series
Interactive Control Engineering: Principles and Applications, Volume 14 of 20
Editor
John D. Hedengren
Publisher
Advanced Process Solutions, LLC, 2026
Pages
327

Contents

  1. 1

    Introduction: Late Measurement and Run-to-Run Correction

    pages 1–22

  2. 2

    Siemens Polysilicon Reactor Simulator for Gain Scheduling and an Unmeasured Constraint

    Siemens Polysilicon Reactor · pages 23–51

    The silicon rods of a Siemens reactor are the heating element and the product, and they grow from 8 to 150 in one batch. How does a temperature loop stay useful while its plant gain falls a hundredfold, and how is the batch ended at a center temperature that no instrument measures?

  3. 3

    Czochralski Crystal Puller Simulator for Mid-Ranging a Fast Limited Actuator

    Czochralski Crystal Puller · pages 52–81

    The pull rate reaches the crystal diameter only through the meniscus, two integrations away, and it has a ceiling that falls as the crystal fattens and that no instrument reports. How is the diameter held without spending that margin, and what does a slow heater loop closed on the pull rate buy?

  4. 4

    Wafer Scanner Simulator for Preview Feedforward Where No Measurement Exists

    Reticle Field Exposure · pages 82–108

    Nothing can measure focus under the exposing slit of a scanner, so the stage is commanded from a level sensor that reads the wafer surface ahead of the slit. How far ahead should it read, why does that distance move whenever the scan speed is raised for throughput, and what is left for feedback to do?

  5. 5

    A Hundred-Zone Bake Plate Simulator for Decentralized Control and Spatial Bandwidth

    100-Zone Bake Plate · pages 109–136

    A hundred zone loops on one conducting plate can each be well tuned and still hold a temperature profile nobody asked for, while the wafer on top prints a linewidth no thermocouple sees. Which of the plate's disturbances does feedback answer, and which need a model, a timed feedforward or a measurement of the product?

  6. 6

    Lithography and Etch Virtual Laboratory for Run-to-Run Control Through a Metrology Queue

    Run-to-Run CD Control · pages 137–162

    A lot of wafers is etched every thirty minutes, and its etched linewidth is reported only after two more lots have run. How hard can a recipe controller push on that loop, and how much of the limit comes from the queue and the bookkeeping rather than from the process?

  7. 7

    A Plasma Etch Simulator for Recipe Trades and Endpoint Detection

    Semiconductor Plasma Etch Reactor · pages 163–187

    The four loops of an etch chamber settle in a small fraction of the time a wafer spends in it and barely interact. What then decides whether a cassette survives a chamber clean: the loop tuning, the recipe setpoints, a model predictive controller, or a detector that decides when to stop?

  8. 8

    An Ion Source Simulator for Cascade Control and Recovery From a Measurement That Stops Meaning Anything

    BF₃ Ion Source and Beam Glitch Recovery · pages 188–211

    A spark across the extraction gap halves the beam voltage in half a millisecond while the cathode, with a time constant of seconds, notices nothing. What should a cascade on the beam do with a measurement that has stopped meaning anything, and what does each choice cost in source heat, beam overshoot and missed dose?

  9. 9

    Rapid Thermal Processing Simulator for Ramp Feedforward and Pyrometer Emissivity Error

    Rapid Thermal Processing Chamber · pages 212–239

    How can five lamp zones follow a spike anneal at 250 when the wafer's gain moves with the cube of its temperature, the zones light each other's pyrometers and the pyrometers may be converting radiance with the wrong emissivity? And what does a loop on its setpoint prove about the wafer it anneals?

  10. 10

    Copper Plating Bath Simulator Dosed by Amp-Hours and Analyzed Every Two Hours

    Copper Electroplating Bath Management · pages 240–264

    A copper plating bath consumes its additives with every amp-hour, while its only analysis arrives every two hours and describes the bath of 42 minutes before. How much of the dosing can such an analysis carry, and what must the amp-hour counter and the bleed do instead?

  11. 11

    A Chemical Mechanical Planarization Simulator for Profile Control Across a Consumable Lifecycle

    CMP Pad Lifecycle and Profile Control · pages 265–289

    Eight carrier head chambers drive thirty-three radial thicknesses while the pad doing the work wears out and is replaced every few days. Which estimator states should survive a pad change, and how many qualification wafers does the answer cost?

  12. 12

    Summary and Outlook

    pages 290–303

Cite