Severity, selectivity and grade from cracker to pellet
Olefin and polymer plants hold product quality that is seldom measured against limits that must never be crossed. Eleven plants cover cracking, purification, polymer reactors and grade transitions.
pages 1–23
Ethane Cracking Furnace · pages 24–47
A cracking furnace comes off line when one tube reaches its metal limit, yet most pass balancing schemes equalize the coil outlet temperatures on the other side of the coke. What does balancing the measured variable do to the run length, and which measurement can find the severity that makes the most ethylene per elapsed hour?
Acetylene Hydrogenation Reactor · pages 48–70
Too little hydrogen puts the whole ethylene product off grade, and too much turns ethylene into ethane and can light off the bed. Where in this one-sided window should the hydrogen sit, and what keeps it there?
Propane/Propylene Superfractionator · pages 71–94
A propylene splitter is about half settled four hours after a reflux step, so its step test does not finish within a shift and a tray temperature must stand in for a product analyzed every twenty minutes. Which tray, which pressure correction and which layer above it hold polymer grade, and what is the analyzer above the tray loop actually for?
Propane Dehydrogenation (Cyclic Fixed Beds) · pages 95–116
A dehydrogenation bed on line spends heat it stored in its last regeneration, so no move reaches the beds now making propylene. How far can a regeneration temperature set once a slot hold the conversion through a lost bed and a feed step, and what does the schedule decide first?
Ethylene Oxide Reactor · pages 117–138
On an ethylene oxide reactor the eighth of the ethylene that burns makes two thirds of the heat, the cool steady state of the tube ends a few degrees above the design coolant, and the chloride that sets the selectivity has a maximum. Which handle protects which limit, what keeps the reactor off its cliff, and why can no fixed-sign loop hold the chloride at its optimum?
Simulated Moving Bed Paraxylene · pages 139–161
A simulated moving bed has no steady state, and its purities exist only as twelve-minute averages reported once a cycle. Which flow-rate ratios keep both outlets on specification, and how much can a correction made once a cycle hold through a richer feed and an aging adsorbent?
Gas-Phase Polyethylene Reactor · pages 162–193
The gas in a fluidized-bed polyethylene reactor settles in minutes to hours, while melt index and density are averages over a four-hour bed of powder. How should cascades that span two decades of time scale be tuned, and what do tuning and bed preparation save in off-specification tonnes during a grade change?
Liquid-Loop Polypropylene Reactor · pages 194–225
In a liquid-full polypropylene loop the hydrogen that sets melt flow rate also raises the bubble point of the liquid toward the pressure the circulation pump needs. How should a quality controller and a margin controller share the one hydrogen setpoint, and what does each arrangement cost in pump damage and in off-specification polymer?
High-Pressure Tubular LDPE Reactor · pages 226–256
Four peroxide injections hold four temperature peaks a few tens of kelvin below the temperature at which ethylene decomposes, and the conversion rises with the peaks. How large must the margin to that line be when a scheduled pulse valve, late thermocouples and a changing initiator lot all make excursions that the setpoints do not show?
Butyl Rubber Slurry Reactor · pages 257–281
A butyl rubber reactor fouls its own cooling surface, and its temperature loop holds the setpoint while the jacket walks toward a refrigeration floor it cannot pass. Which trend shows how much of the run is left, what reactor temperature gives the most saleable rubber per elapsed hour, and what should decide when to wash?
Weigh Feeder Additive Control · pages 282–304
A loss-in-weight feeder holds the flow its scale weighs, but the product sees only what leaves the discharge sock below the scale and a laboratory reports it hours late. Which faults does the weighing loop correct, which can it not see, and what do a laboratory trim, a moving horizon estimator and a predictive controller add?
pages 305–318