Cover of Volume 11: a fired heater, crude tower and catalytic cracker
Industry applications · Volume 11

Control in Petroleum Refining

Throughput, quality and limits from crude unit to blending

A refinery is a chain of heat-integrated units, each pushed against a different limit. Fourteen plants follow crude oil from the desalter through distillation, conversion and treating to the blender.

Series
Interactive Control Engineering: Principles and Applications, Volume 11 of 20
Editor
John D. Hedengren
Publisher
Advanced Process Solutions, LLC, 2026
Pages
418

Contents

  1. 1

    Introduction: Throughput, Quality and Limits in a Refinery

    pages 1–22

  2. 2

    Crude Desalter Simulator With a Mixing Optimum and a Misread Rag Layer

    Crude Desalter · pages 23–49

    Harder mixing contacts more brine but makes drops too small to settle, and the interface probe reads part of the rag as water. Where should the mixing pressure drop sit when the crude changes, and what does a loop on that reading do to the true water and the grid?

  3. 3

    Fouling Crude Preheat Train Simulator for Override Control on Throughput

    Crude Preheat Train and Furnace · pages 50–80

    Fouling and cleaning outages take the fuel valve to its stop. What does holding the column inlet then cost in throughput, and how should an override that cuts the charge be set?

  4. 4

    A Crude Atmospheric Tower Simulator for Degrees of Freedom and Triangular Interaction

    Crude Atmospheric Main Fractionator · pages 81–103

    A crude tower cuts one boiling curve into four products, each with two end specifications, using four handles. Which four of the eight numbers can be held, which way do the draws interact, and in what order should the loops be brought into service?

  5. 5

    Vacuum Tower Cut Points Held by an Ejector Curve That Breaks

    Vacuum Distillation Unit · pages 104–126

    The flash-zone pressure is the cheapest handle on a vacuum tower's cut, but the ejectors that hold it break at a load the cooling water sets and recover only well below it. How far can the cut be pushed, and what must a lift controller watch?

  6. 6

    Fluid Catalytic Cracking Simulator for Internal Heat Balance Feedback and Selective Control

    Fluid Catalytic Cracking Riser and Regenerator · pages 127–160

    A cat cracker has no furnace: its only heat is the coke it burns. How much does that internal heat balance amplify and slow every move, and how should one feed rate be shared among equipment limits that move with the weather, the feed and the severity?

  7. 7

    A Hydrocracker Reactor Simulator for Open-Loop Instability and Layered Protection

    Hydrocracker Reactor · pages 161–183

    An adiabatic catalyst bed with an exponential rate law can be unstable before any controller is added, and one number decides it. How close is the first bed to that boundary, and which layers of control and protection can still act once a feed cut or a hotter catalyst pushes it there?

  8. 8

    A Diesel Hydrotreater With Two Inlet Handles and a Half-Hour Sulfur Analyzer

    ULSD Hydrotreater with Feed–Effluent Exchanger · pages 184–207

    A diesel hydrotreater heats its feed with its own effluent and learns its product sulfur from an analyzer half an hour late. Which handle should hold the reactor inlet, and what can a sulfur loop, a Smith predictor or a predictive controller do before the analyzer reports?

  9. 9

    Interheater Coordination and Inferred Octane on a Continuous Catalytic Reformer

    Continuous Catalytic Reformer · pages 208–232

    A reformer's beds absorb the heat its interheaters add, and its octane is measured late, rarely or by inference. Which layers of control hold that octane through a leaner naphtha, a heater short of duty and an analyzer that drifts, and at what cost in yield?

  10. 10

    Three Clocks Behind One Octane in a Sulfuric Acid Alkylation Unit

    Sulfuric Acid Alkylation Unit · pages 233–261

    The octane of a sulfuric acid alkylation unit rests on three stocks that answer on three clocks, the contactor's cold in minutes, the recycle's isobutane in hours and the acid's strength in more than a day, while the acid is titrated only every four hours. Which loops, sensors and supervisors hold the octane and the acid bill through a day of upsets, and where does each of them lose?

  11. 11

    A Delayed Coker Whose Drum Switch Is a Disturbance Known in Advance

    Delayed Coker · pages 262–283

    A delayed coker's two drums take turns on a fixed cycle while its furnace and fractionator run without a pause, and every switch sends the charge into a drum colder than its vapor. How much of that upset can control remove when the schedule that causes it is known hours ahead, and what can only the drum's warm-up prevent?

  12. 12

    A Hydrogen Plant Whose Steam Must Lead Its Feed and Whose Waste Is Its Fuel

    Hydrogen Plant: Steam Methane Reformer and PSA · pages 284–307

    A hydrogen plant must keep its slow steam ahead of a fast feed, and it burns whatever hydrogen its adsorber does not recover. Which structure keeps the steam-to-carbon ratio above its floor through a rate change, and how does the adsorber's recovery reach the furnace?

  13. 13

    A Claus Sulfur Recovery Simulator for Feedforward, Dead Time and an Optimum Turned Into a Zero

    Claus Sulfur Recovery Unit · pages 308–328

    Sulfur recovery has a maximum at one air rate, and a maximum has no sign, yet an ordinary PI loop holds the air of every Claus unit. What measurement makes that possible, and with the analyzer minutes downstream of the furnace, what do tuning, feedforward and a Smith predictor each do to the error a feed change leaves?

  14. 14

    A Refinery Fuel Gas Header That Should Never Import and Flare at Once

    Refinery Fuel Gas Header and Flare · pages 329–352

    A refinery fuel gas header holds well under a minute of its throughput, and one pressure controller splits its output between a natural gas makeup valve and a flare valve that pass money in opposite directions. How should that split range, the flare gas recovery and the heaters' firing be set so that the refinery never buys gas while it flares its own?

  15. 15

    Gasoline Blending Simulator Whose Octane Authority Shrinks as the Tank Fills

    Gasoline Blending to Specification · pages 353–377

    Gasoline is certified from a sample of its full product tank, so the blender is judged on the average of everything it has made, while every loop works on the header. How should a late analyzer, a biased blend model and a recipe optimizer be layered so that the tank lands on its octane target, when a deficit already in the tank can only be repaid by the blend still to come?

  16. 16

    Summary and Outlook

    pages 378–391

Cite