Cover of Volume 10: a drilling rig, an offshore platform and a pipeline to a storage tank
Industry applications · Volume 10

Control in Upstream and Midstream Oil and Gas

From the wellbore to the terminal

Wells, flowlines, gas plants and pipelines run far from their operators and close to their pressure limits. Fourteen plants follow the control problems from drilling and production through gas processing, transmission and LNG.

Series
Interactive Control Engineering: Principles and Applications, Volume 10 of 20
Editor
John D. Hedengren
Publisher
Advanced Process Solutions, LLC, 2026
Pages
418

Contents

  1. 1

    Introduction: Pressure, Inventory and Limits From Well to Market

    pages 1–23

  2. 2

    A Managed Pressure Drilling Simulator to Teach Optimization on a Constraint Boundary

    Drilling Optimization and MPD · pages 24–54

    Weight on bit, rotary speed and a lower bottomhole pressure all raise the drilling rate, and each also pushes the well toward a vibration, cuttings or pressure limit. Where does the best feasible operating point sit, what holds it there, and what does operating away from it cost?

  3. 3

    Hydraulic Rod Pump Simulator for Downhole Card Inference and Constrained Rate Control

    Hydraulic Rod Pump Control · pages 55–79

    The only routine instrument on a rod-pumped well is a load cell nine hundred meters above the pump. How far can a controller trust the fillage and fluid level it infers from that card, and which rate and stroke lift the most oil without overloading or fatiguing the rods?

  4. 4

    Fast Choke Overrides and Slow Waterflood Planning in a Smart Well Simulator

    Smart Wellhead and EOR Control · pages 80–105

    A production choke changes the rate of an oil well within minutes, but the water it produces was injected weeks earlier, and the layer that water came through decides how much oil the flood leaves behind. How do fast choke overrides and a slow plan for the sweep share one well, and why do the settings that make the most oil this month recover less by the end of a campaign?

  5. 5

    A Deepwater Flowline Simulator for Hydrate Control at the Weakest Point

    Deepwater Flowline and Hydrate Control · pages 106–134

    Gas hydrates form wherever the liquid in a subsea line is colder than an equilibrium that climbs with pressure and falls with the methanol in its water, so the constraint is a minimum over kilometers of pipe whose location moves. How is methanol dosed at the tree for a margin that is judged hours downstream, and what can an estimate built from a few transmitters tell the dose?

  6. 6

    Offshore Three-Phase Separator Simulator for Slug Absorption and Delayed Quality Measurement

    Offshore Three-Phase Separation · pages 135–163

    A riser slug arrives far faster than any outlet valve can pass it, and the analyzers on the oil and water outlets report minutes late. If the separator must store the slug whatever the tuning, what does the level tuning decide, and what keeps the export oil and the overboard water in spec when the measurement arrives after the water has gone?

  7. 7

    Glycol Dehydration Simulator With an Equilibrium Floor and a Reboiler Ceiling

    Glycol Dehydration Unit · pages 164–188

    One water specification on the dry gas has two handles: glycol circulation, which acts in minutes but only down to a floor set by equilibrium with the lean glycol, and glycol purity, which moves that floor but reaches the contactor only as the surge drum turns over and is capped by the reboiler ceiling. When is each handle worth its energy, and what goes wrong when a loop reaches for the wrong one?

  8. 8

    Selective Amine Sweetening With Delayed Analysis and Loading Protection

    Amine Gas Sweetening · pages 189–209

    A sweetener must keep hydrogen sulfide in the sales gas under 4 ppm, but its analyzer reports each sample minutes after the gas has gone, and a cap on the rich amine loading protects the plant where that analyzer cannot see. Which measurement can protect which limit, and what does each defense cost in steam?

  9. 9

    Ethane Recovery and Rejection Through a Sequenced Turboexpander Plant

    Turboexpander NGL Recovery Plant · pages 210–229

    When ethane is worth less as a liquid than as gas, a gas plant moves its demethanizer from ethane recovery to rejection and back, while a chromatograph reports the methane in its liquid product minutes late. In what order must the column pressure and the tray temperature move, and what does the move cost?

  10. 10

    An NGL Fractionation Train Simulator for Plantwide Pairing and Shared Constraints

    Gas Plant NGL Fractionation Train · pages 230–252

    Ethane in the propane product is measured on the depropanizer, set by the deethanizer cut one column upstream, and three reboilers share one steam header. Which valve owns each specification, which measurement can see a drifting soft sensor, and which product loses when the header runs short?

  11. 11

    Load Sharing by Equal Surge Margin Among Three Compressors on One Header

    Compressor Station Load Sharing · pages 253–275

    Compressors on one header share a head, not a load, so a machine a little slower or a little fouled drifts toward surge while its neighbors take the gas. Which sharing law, start sequence and trip action keep every machine out of surge and off its recycle while the station holds its pressure?

  12. 12

    A Gas Transmission Line Simulator for Line Pack, Forecast Feedforward and Leak Detection

    Transmission Pipeline Line Pack and Delivery · pages 276–297

    A transmission line stores its own gas and takes most of an hour to pass a station change to the city gate, which must stay above a contract floor. What must the station's control see, and how small a leak can a mass balance on three pressure transmitters find?

  13. 13

    Series Pump Stations, Batches and Surge on a Refined Products Pipeline

    Refined Products Pipeline · pages 298–320

    One flow passes every pump station of a refined products line, while its batches move at walking pace and its pressure news at the speed of sound. Which controller may set that flow, what must the other stations hold, and what protects the line when a valve closes, a station trips, a batch changes or a hill near the terminal runs slack?

  14. 14

    An LNG Liquefaction Simulator for Loop Pairing and Inferential Constraint Control

    LNG Mixed-Refrigerant Liquefaction Train · pages 321–352

    The Joule-Thomson valve of a mixed refrigerant train sets the circulation and the suction pressure together, and the two reach the LNG temperature with opposite signs, while the closest approach inside the exchanger is computed from an analysis twelve minutes old. Which loop structure makes the valve a usable handle, and what does holding an inferred limit cost when its input goes stale?

  15. 15

    An LNG Import Terminal Whose Boil-Off Can Only Leave With Its Send-Out

    LNG Regasification Terminal · pages 353–376

    The boil-off of an LNG import terminal can leave only by condensing into the LNG it sends out, so the outlet of an integrating tank pressure shrinks with a flow the market sets. How low can the send-out go before the tanks reach the flare, and how much of a low-demand night can a published nomination prepare the tanks for?

  16. 16

    Summary and Outlook

    pages 377–390

Cite